Download Print this page
Enerpac P142E014 Instruction Sheet
Enerpac P142E014 Instruction Sheet

Enerpac P142E014 Instruction Sheet

Foot pump

Advertisement

Quick Links

L2176
Rev. O
IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. If any
shipping damage is found, notify carrier at once. Shipping
damage is NOT covered by warranty.
responsible for all repair or replacement cost resulting from
damage in shipment.
SAFETY INFORMATION
To avoid personal injury or property damage during system
operation, read and follow all CAUTIONS, WARNINGS, and
INSTRUCTIONS included with or attached to each product.
The manufacturer CANNOT BE RESPONSIBLE FOR
DAMAGE OR INJURY RESULTING FROM UNSAFE USE OF
PRODUCT, LACK OF MAINTENANCE, OR INCORRECT
PRODUCT AND SYSTEM APPLICATIONS. Contact the
manufacturer when in doubt as to safety precautions or
applications.
CAUTION: Always use the handle to carry the
pump. Carrying the pump by the hose may
damage the hose and or the pump.
WARNING: Make sure that all system components
are protected from external sources of damage,
such as excessive heat, flame, moving machine
parts, sharp edges, and corrosive chemicals.
WARNING: Always check product limitations
regarding pressure ratings, load capacities, and
set-up requirements. The system operating
pressure must not exceed the pressure rating of the
lowest rated component in the system.
WARNING: NEVER set the relief valve to a higher
pressure than the maximum rated pressure of the
pump. Higher settings may result in equipment
damage and/or personal injury. See chart above for the
maximum pressure rating.
SPECIFICATIONS
Maximum Pressure Rating
Speed
First stage:
2
200 (14)
A
Release Valve
B
NPTF Outlet Port
C
Vent / Fill Cap
®
07/97
The carrier is
psi (bar)
Second stage:
10,000 (700)
A
Figure 1 - Components of Pump
INSTRUCTION SHEET
P142E014 - FOOT PUMP
DESCRIPTION
Figure 1 shows the main components of the pump. The dual-
purpose vent/fill camp acts as a pressure relief valve in case
of accidental reservoir pressurization. To provide an access
port at the rear of the reservoir for remote valves, use a
return-to-tank kit (model number PC-20).
INSTALLATION
Connecting the Pump
1.
Thread hose into pump outlet. Use 1fi wraps of Teflon
tape (or suitable thread sealant) on the hose fitting,
leaving the first thread completely free of tape to ensure
that tape does not shed into hydraulic system, causing
damage.
2.
Install a pressure gauge in-line from the pump for added
safety and better control.
3.
Connect the hose to your cylinder or tool.
Pump Venting
This pump may be operated in a vented or unvented position.
(Vented pumps provide slightly better performance.) To vent,
turn the vent/vill cap counter-clockwise ⁄ turn. Close vent
prior to transporting pump to prevent leakage.
OPERATION
Before Using the Pump
1.
Check all system fittings and connections to be sure they
are tight and leak free.
2.
Check oil level in reservoir before operating pump. See
"Adding Oil to the Pump" on page 2.
Pumping / Using the Release Valve
1.
Operate pump foot pedal to deliver hydraulic power to
system. Hydraulic pressure will be maintained until
release valve is open.
Oil Volume per stroke
in
3
(cm
3
)
First stage:
Second stage:
.221 (3.62)
.055 (.90)
B
Usable Oil Capacity
in
3
(cm
3
)
20 (328)
C

Advertisement

loading
Need help?

Need help?

Do you have a question about the P142E014 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enerpac P142E014

  • Page 1 INSTRUCTION SHEET ® P142E014 - FOOT PUMP L2176 Rev. O 07/97 IMPORTANT RECEIVING INSTRUCTIONS DESCRIPTION Visually inspect all components for shipping damage. If any Figure 1 shows the main components of the pump. The dual- shipping damage is found, notify carrier at once. Shipping purpose vent/fill camp acts as a pressure relief valve in case damage is NOT covered by warranty.
  • Page 2 Changing the Oil The reservoir should be drained and refilled with Enerpac oil at least once every 12 months. If the pump is used in dirty environments, the oil should be changed more often.
  • Page 3 Problem Possible Cause Solution Oil level in pump reservoir is low. Add oil. See page 2. Release valve open. Close release valve. Check that couplers are fully Loose hydraulic coupler. tightened. Cylinder does not advance, Load is too heavy. Do not lift more than recommended advances slowly, or advances in load.
  • Page 4 Tel: +82 31 434 4506 122804 Fax: +82 31 434 4507 All Enerpac products are guaranteed against defects in workmanship and materials for as long as you own them. For your nearest authorized Enerpac Service Center, visit us at www.enerpac.com...