Enerpac Ultima P-18 Instruction Sheet

Enerpac Ultima P-18 Instruction Sheet

Hand pumps
Hide thumbs Also See for Ultima P-18:

Advertisement

POWERFUL SOLUTIONS. GLOBAL FORCE.
L3070
Rev. E
05/12
Index:
English ............................................................... 1-9
Français ......................................................... 10-18
Deutsch ........................................................ 19-27
Italiano .......................................................... 28-36
Español ......................................................... 37-45
Nederlands ................................................... 46-54
Portuguese ................................................... 55-63
........................................................... 64-71
.......................................................... 72-79
Finnish ........................................................... 80-88
Norwegian ..................................................... 89-97
Svenska ....................................................... 98-106
Russian ...................................................... 107-115
Greek ......................................................... 116-125
Repair Parts Sheets for this product are available
from the Enerpac web site at www.enerpac.com, or
from your nearest Enerpac Authorized Service Center
or Enerpac Sales office.
1.0 IMPORTANT RECEIVING
INSTRUCTIONS
Visually inspect all components for shipping damage.
Shipping damage is not covered by warranty. If
shipping damage is found, notify carrier at once. The
carrier is responsible for all repair and replacement
costs resulting from damage in shipment.
SAFETY FIRST
2.0 SAFETY ISSUES
Read
warnings
carefully. Follow all safety
precautions to avoid personal injury or property
damage during system operation. Enerpac cannot be
responsible for damage or injury resulting from unsafe
product use, lack of maintenance or incorrect product
and/or system operation. Contact Enerpac when in
doubt as to the safety precautions and operations. If
you have never been trained on high-pressure
hydraulic safety, consult your distribution or service
center for a free Enerpac Hydraulic safety course.
Failure to comply with the following cautions and
warnings could cause equipment damage and
personal injury.
A CAUTION is used to indicate correct operating or
maintenance procedures and practices to prevent
damage to, or destruction of equipment or other
property.
A WARNING indicates a potential danger that
requires correct procedures or practices to avoid
personal injury.
A DANGER is only used when your action or lack of
action may cause serious injury or even death.
ULTIMA Series Hand Pumps
P-18, P-39, P-77, P-80, P-801 and P-84
has been raised or lowered, it must always be
blocked mechanically.
supporting the load. Never use a hydraulic cylinder
as a shim or spacer in any lifting or pressing
application.
all
instructions,
and
cautions
failure and possible personal injury. The cylinders are
designed for a max. pressure of 700 bar [10,000 psi].
Do not connect a jack or cylinder to a pump with a
higher pressure rating.
maximum limit is exceeded. Damage to pump and
components may also occur.
system to monitor operating pressure. It is your
window to what is happening in the system.
Instruction Sheet
WARNING:
Wear
proper
protective gear when operating hydraulic
equipment.
WARNING: Stay clear of loads supported
by hydraulics. A cylinder, when used as a
load lifting device, should never be used
as a load holding device. After the load
WARNING: USE ONLY RIGID PIECES
TO HOLD LOADS. Carefully select steel
or wood blocks that are capable of
DANGER: To avoid personal injury
keep hands and feet away from cylinder
and workpiece during operation.
WARNING: Do not exceed equipment
ratings. Never attempt to lift a load
weighing more than the capacity of the
cylinder. Overloading causes equipment
WARNING: Never set the relief valve
pressure above 10,500 psi [725 bar].
Serious personal injury could result if this
WARNING:
The
system
pressure must not exceed the pressure
rating of the lowest rated component in
the system. Install pressure gauges in the
personal
operating

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultima P-18 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enerpac Ultima P-18

  • Page 1 Repair Parts Sheets for this product are available protective gear when operating hydraulic from the Enerpac web site at www.enerpac.com, or equipment. from your nearest Enerpac Authorized Service Center or Enerpac Sales office. WARNING: Stay clear of loads supported 1.0 IMPORTANT RECEIVING...
  • Page 2: Product Information

    If oil is injected under the skin, see a doctor causing personal injury and property immediately. damage. ENERPAC parts are designed to fit properly WARNING: Only use hydraulic cylinders in and withstand high loads. a coupled system. Never use a cylinder CAUTION: Always use the pump lifting/ with unconnected couplers.
  • Page 3 3.1 Pump Features and Major Components See figures 1 through 4 for the locations of pump features and major components. Refer to Table 2 for descriptions of items A through G. Figure 1, Models P-18 and P-39 Figure 3, Models, P-80 and P-801 Figure 2, Model P-77 Figure 4, Model P-84...
  • Page 4: Installation

    Note: Cylinders, hoses and accessories shown in Figure 5 are sold separately and not included 3. Connect hose(s) with pump. Refer to the Enerpac catalog for a pump. To seal threads, Figure 6 complete description of available components and use anaerobic thread sealer, accessories.
  • Page 5: Operation

    CAUTION: Never add extensions to pump to turn or becomes stuck, immediately handle. Extensions cause unstable pump discontinue using pump. Have pump operation. inspected and repaired by an Enerpac Authorized CAUTION: prevent mechanical Service Center. damage, do not pull on pump handle after it has reached the end of its travel.
  • Page 6: Air Removal

    5.4 Pump Operation - Model P-84 2. Operate pump to perform work. 3. Change valve positions as needed. The model P-84 is equipped with a 4-way, 3-position WARNING: Operate double-acting control valve. It is designed for use with double- cylinder only when both hoses are acting cylinders.
  • Page 7 If needed, readjustment should be 7. Model P-84 only: After the desired setting is performed only by an Enerpac Authorized Service obtained, move the valve handle to the (N) neutral Center.
  • Page 8: Maintenance

    Drain all oil from reservoir and refill with clean Use only Enerpac hydraulic oil with the pump to Enerpac oil every 12 months. If pump is used in dirty promote long pump life and to protect your warranty. environments, change the oil more frequently.
  • Page 9 6. Have cylinder serviced by an Enerpac Authorized damage. Service Center. 7. In-line valve closed. 7. Ensure that in-line valves (if used) are correctly set. Note: For the location of your nearest Enerpac Authorized Service Center go to www.enerpac.com...
  • Page 10 +49 211 471 490 +34 91 884 86 06 sales-us@enerpac.com +49 211 471 49 28 +34 91 884 86 11 All Enerpac products are guaranteed against sales-de@enerpac.com sales-es@enerpac.com defects in workmanship and materials for as long as you own them.