Download Print this page
CESVA SC160 Manual

CESVA SC160 Manual

Integrating sound level meter
Hide thumbs Also See for SC160:

Advertisement

Quick Links

Applications
Evaluation of the noise exposure of
workers at workplace simultaneously
to the verification of PPE (Personal
Protective Equipment)
Room acoustics: NC and NR evalua-
tion, measurement of the reverbera-
tion time
Evaluation of noise from machinery
Sound insulation inspections
User friendly
Measures all parameters simultane-
ously with A, C and Z frequency
weightings
One single range 30-137 dBA; up to
140 dB peak
Backlit graphic screen and soft touch
keyboard for easy use
Features
Class 2 integrating sound level meter
meeting IEC 61672, IEC 60651:01 class
2, IEC 60804:00 type 2, ANSI S1.4:83
(A1 :85), ANSI S1.43:97 standards
Real time octave band spectrum ana-
lyser* 31.5 Hz–16 kHz. ANSI S1.11:86
Real time room noise evaluator by NC
and NR curves
Reverberation time measurement in
real time for octave bands (Optional)
Measurement results can be stored in
the memory
Includes software and cable for real
time retrieval of all the measured and
recorded data and their transmission
to a PC
Real time data transmission through
wireless communication system Blue-
®
tooth
Detachable microphone for use of the
extension cable (CNR-ITV)
Stores in memory the time and date of
the last time the sensitivity was modi-
fied
*ATTENTION
: The Spectrum Analyser
mode in octave bands is optional. Refer-
ence number SC160sb does not have
this option. If you wish to incorporate it
you should acquire module FB160. Refer-
ence number SC160cf does incorporate
the analyser mode in octave bands
SC160
Integrating Sound Level Meter
Real time frequency Analyser* in Octave Band
The
SC160
sound level meter and real time octave band spectrum ana-
lyser* that allows you to make sound measurements quickly,
conveniently and easily. It has a single range, so there is no
need to make any range adjustments.
The
SC160
function mode (sound level meter or spectrum analyser*) with
A, C, and Z frequency weightings . The SC160's graphic
screen provides graphical and numerical representation of the
functions measured.
The data measured and recorded by the
ferred to a personal computer so that they are available in
electronic format. The AC output allows you to
obtain the signal from the preamplifier and
make a calibrated recording on D.A.T.
The microphone is detachable. It can therefore
be uncoupled and moved away from the
by means of an extension cable (CNR-ITV).
The
SC160
meter or a spectrum analyser* and room
noise evaluator by NC and NR curves.
The sound level meter mode is ideal for
measuring overall sound pressure lev-
els. The
SC160
ures all functions with all frequency
weightings and calculates statistical
data as maximum and minimum val-
ues and percentiles.
The spectrum analyser* mode allows
you simultaneously and in real time
to measure the sound levels and
peak levels for octave bands from
31,5 Hz to 16 kHz and the overall
sound pressure levels and peak lev-
els A, C and Z with frequency weight-
ings.
Within the analyser* mode there is a
special screen to evaluate room noi-
se, especially designed for HVAC
system installers, engineers, and
consultants, that allows you to asses
noise in real time using the NC and
NR curves criterion.
.
.
is a user-friendly, low cost, class 2 integrating
simultaneously measures all the functions for each
can be used as either a sound level
simultaneously meas-
SC160
can be trans-
SC160

Advertisement

loading

Summary of Contents for CESVA SC160

  • Page 1 (sound level meter or spectrum analyser*) with • One single range 30-137 dBA; up to A, C, and Z frequency weightings . The SC160’s graphic 140 dB peak screen provides graphical and numerical representation of the •...
  • Page 2 NR curve not exceeded by the measured spectrum in the f band. (See graphic below) X: Frequency weighting A, C and Z 31,5 Villar, 20 - 08041 Barcelona (Spain) - Tel. (34) 934.335.240 - Fax. (34) 933.479.310 - e-mail: info@cesva.com - www.cesva.com...
  • Page 3 Special outdoors transport briefcase (51x38x15 cm) IM003 Printer 40 columns serial RT-030 Reverberation time module TK1000 Outdoor kit Mains feeder A-200 and battery converter Villar, 20 - 08041 Barcelona (Spain) - Tel. (34) 934.335.240 - Fax. (34) 933.479.310 - e-mail: info@cesva.com - www.cesva.com...
  • Page 4: Storage Capacity

    In the memory of the SC160 may be stored the final results of a measurement or continuous recordings of functions with program- mable register time. Villar, 20 - 08041 Barcelona (Spain) - Tel. (34) 934.335.240 - Fax. (34) 933.479.310 - e-mail: info@cesva.com - www.cesva.com...
  • Page 5: Technical Specifications

    Sensitivity to 137 dB and 1 kHz (Gain = 0dB): 3,8 Vrms (max) Upper limit: 7 Vpeak ; Output impedance: 100 Ω Gain: 0 and 40 ± 0,2 dB Villar, 20 - 08041 Barcelona (Spain) - Tel. (34) 934.335.240 - Fax. (34) 933.479.310 - e-mail: info@cesva.com - www.cesva.com...
  • Page 6 Dimensions and weight Dimensions: 294 x 82 x 19 mm Weight: • With battery: 508 g • Without battery: 466 g Villar, 20 - 08041 Barcelona (Spain) - Tel. (34) 934.335.240 - Fax. (34) 933.479.310 - e-mail: info@cesva.com - www.cesva.com...
  • Page 7 SC160, it runs in PC with Windows 9x/Me/2000/ NT/XP/VISTA/7. Room noise evaluation (NC curves) The characteristics, technical specifications and accessories may vary without prior notice Villar, 20 - 08041 Barcelona (Spain) - Tel. (34) 934.335.240 - Fax. (34) 933.479.310 - e-mail: info@cesva.com - www.cesva.com...
  • Page 8: Reverberation Time Module

    RT values will appear on the screen of the SC160. Maximum level (L + ∆) ∆ Background noise L Villar, 20 - 08041 Barcelona (Spain) - Tel. (34) 934.335.240 - Fax. (34) 933.479.310 - e-mail: info@cesva.com - www.cesva.com...