Configuration Se/Cs Plc Assignment Table - Bosch Rexroth Tightening System 350 Manual

Table of Contents

Advertisement

580/641
Bosch Rexroth AG | Tightening Technology
7.5.4.3
Sending/saving data
Tightening programs have to be sent to the tightening controller before they can be used. They can also
be stored as files on the PC (see
7.5.5

Configuration SE/CS PLC assignment table

The PLC assignment table defines the assignment of the control signals to the tightening controller's
physical interfaces. The tightening controller can be integrated into a system sequence with these control
signals. The following number of inputs and outputs are available on the interfaces:
Table 7–24:
System component
ErgoSpin
IMpdp
IMdev
IMpnio, IMpnio2
IMenip, IMenip2
IMmtcp
IMecat
IM24V
HMI
HVO
IL
OP
XML
A maximum of 256 input and output signals can be used.
With automatic channel configuration, the PLC assignment table is created in accordance with the
presettings when the compact system is commissioned with the ErgoSpin. It can be loaded from the
compact system by selecting System  SE/CS PLC assignment table.
Information on the configuration of the PLC assignment table can be found in section
page
Send the preset PLC assignment table to the tightening controller; it can also be stored as a file on the
PC (see
The detailed description of the control signals can be found in chapter
Sending and saving (page
Number of inputs and outputs
Number of inputs/outputs SE
4/0
5/6
123.
Sending and saving (page
542)).
Number of inputs/outputs CS
4/0
16 to 64/16 to 64
16 to 64/16 to 64
0 to 64/0 to 64
16 to 64/16 to 64
16 to 64/16 to 64
16 to 64/16 to 64
10/13
8/0
8/8
32/32
33/24
22/25
542)).
System 350 | 3 608 878 300/2019-03
3 608 878 300
„PLC signals" on
Control signals from page
121.