Table 6–98:
Parameter
OK counter limit
OK counter value
Tightening status
MID 0061 revision 001
Comments
– Start as a single channel (SE/CS): Presetting of the OK counter set
value
– KE application start: Default value is 0
– Rexroth OP/Rexroth OP-BMW: Exception if MID61/MID65
evaluation and batch information from application result is
selected in the configuration for Open Protocol: If the application is
parameterized from the job with a counter, the set value of the OK
counter is returned.
The value consists of four ASCII characters.
ID
Value range
Presetting
Example:
OK counter limit
Value
– Start as a single channel (SE/CS): Actual value of the OK counter
– KE application start: Default value is 0
– Rexroth OP/Rexroth OP-BMW: Exception if MID61/MID65
evaluation and batch information from application result is
selected in the configuration for Open Protocol: If the application is
parameterized from the job with a counter, the actual value of the OK
counter is returned.
The value consists of four ASCII characters.
ID
Value range
Presetting
Example:
OK counter value 4
Value
– Rexroth OP/Rexroth OP-BMW:
– 0: NOK
– 1: OK
Exception if MID61/MID65 evaluation and batch information from
application result is selected in the configuration for Open Protocol:
In application operation, the evaluation of the application for the
tightening status is applied.
– Rexroth OP-Ford:
– 0: NOK
– 1: OK
– 2: Loosen
– 3: Quality code "Start-up test"
– 4: QCode "(C)CW=0"
– 5: Quality code "TorqL"
The setting MID61/MID65 evaluation and batch information from
application result in the configuration for Open Protocol has no
effect.
The value consists of one ASCII character.
ID
Value range
Presetting
Example:
Tightening status OK
Value
07
0000 – 9999
– No presetting for single channels
– Fixed value 0001 when starting in an application
12
0012
08
0000 – 9999
– No presetting for single channels
– Fixed value 0001 when starting in an application
0004
09
0 – 5
-
1
System 350 | 3 608 878 300/2019-03
3 608 878 300
Bytes
2
4
2
4
2
1

Hide quick links: