4.7 Make a Batch file

Since the DLP optical machine is configured on the GUI, the setting will be reset
to the default configuration after power off and restart. Sometimes, customers want
the module to start according to their own configurations. Batch file is a configuration
file used to control the default startup state of the module.
The following content demonstrates how to make a Batch file.
batch file cannot be used directly. You can contact the engineers of Bopixelg to
complete the firmware production together.
generated. After the user burns the new firmware, the module can realize the
customized default state.
(1) Connect the OPR407 module to the computer and ensure normal communication
with the GUI. Click the "Advanced" button to enter the advanced control mode.
(2) After opening the
Advanced
window, it will automatically connect by default.
"
"
33
After configuration, a new firmware is
The produced