Xantrex Freedom 458 Owner's Manual page 8

Inverter/charger basic remote
Hide thumbs Also See for Freedom 458:
Table of Contents

Advertisement

LED Indication
Fault LED
OVERTEMP On
BATTERY STATE
Empty blinking
BATTERY STATE
Empty On
15.5 VDC blinking
(31.0 VDC in 24 V system)
AC IN blinking
INVERT blinking
CHARGE blinking
NOTE: For error conditions not shown above, disconnect Freedom Remote Control Panel for 30 seconds, verify that phone
cable is plugged in at remote and inverter/charger and verify that batteries are above 10 VDC. If condition presists, discon-
nect incoming AC power from inverter/charger and remove positive battery lead for 30 seconds.
Error Detected
OFF
Over-temperature shutdown.
ON
Low Battery Shutdown.
(too low to continue inverting)
ON
Battery Overload.
(excessive ripple voltage during charge) DC Loads. Restart Charger.
ON
High battery shutdown.
ON
AC Backfeed
(external AC power detected at inverter wiring.
output).
ON
Inverter overload
(too much AC load on inverter).
ON
Charger overload
(Battery voltage too low to charge).
Possible Solution
Increase air circulation and allow to cool.
Charge batteries.
Select lowest Power Share setting. Turn off
Check other charging sources connected to
the battery.
Disconnect Incoming AC power and correct
Reduce AC load on inverter. Reset by pressing
INVERT Off and On.
Check batteries. Turn Off all DC loads.
Restart charger.

Advertisement

Table of Contents
loading