IMPORTANT!
Two magnets are pre-installed to the bottom corners of the toe kick mounting plate. Each
magnet has double-sided tape to be attached to the toe kick. This allows both Stainless
steel and Custom panels to be attached to the magnet.
Installing the toe kick mounting plate and toe kick
If the toe kick depth is less than 3 5/8" (92mm), attach the air toe kick seal (A) to the
1
middle of the back side of the mounting plate (B).
Attach the toe kick mounting plate (C) to the plinth.
2
C
Peel off the adhesive tape backing of the magnets located at the front bottom
3
corners of the toe kick mounting plate (D).
B
A
D
@1
 INSTALL TOE KICK
Required components/tools:
1x Air toe kick seal
1x Toe kick
Place the toe kick in front of the mounting plate. Ensure that the spacers at back of the toe
4
kick are aligned with the magnets (E).
– For custom toe kick, skip step
Attach the toe kick by pressing onto the mounting plate (F).
5
– For stainless steel: Ensure the adhesive tape of the magnets adhere to the spacers of
the toe kick.
– Ensure the bottom of the toe kick contacts the floor as you attach to the mounting plate.
IMPORTANT!
For toe kick heights 4 1/2" – 5" (114 – 127mm), shorten the lower grille by cutting along
the vertical ribs.
For 2" (51mm) toe kick height, an additional lower grille can be ordered.
For toe kick heights greater than 5" (127mm), lower grille is not required.
Refer to 'Door and toe kick panel dimensions' for more information.
as spacers are not needed.
3
F
E
35