Case Specifications - Hussmann R3H Installation And Operation Manual

Hot service/self-service/ case with self service front
Hide thumbs Also See for R3H:
Table of Contents

Advertisement

BTU
REQ
TEMPERATURE
LENGTH
PER
EVAP CASE DISC
FT
TMP TMP TMP
R3H Hot& Cold
Determine case loads by combining Cold Prep and Hot Top sections of the Hot and Cold Case Specs.
R3 Refrigerated Self Service Front
4'
650
15° 36° 24°
6'
650
15° 36° 24°
8'
650
15° 36° 24°
10'
650
15° 36° 24°
12'
650
15° 36° 24°
R3H (Hot Top Only)
GRIDDLES
NUMBER
LENGTH
QTY.
SIZE
SHELVES
4'
1
4'
6'
1
6'
8'
2
4'
10'
3
3' & 4'
12'
3
4'
R3H Hot/Cold Combo
Use "R3P Prep Top (Front Section Only)" on the previous page in addition to the above Hot Top
R3H Hot Front
4'
1
4'
6'
1
6'
8'
2
4'
10'
3
3' & 4'
12'
3
4'
R3HTO
( Stand Alone Circulated Hot Air Merchandiser)
12" x 20"
Well Openings Griddle
LENGTH
QTY.
QTY
4'
3
1
6'
5
1
8'
7
1
10'
9
1
12'
11
1
R3HATO
( Stand Alone Circulated Hot Air Merchandiser)
12" x 20"
Well Openings Griddle
LENGTH
QTY.
QTY
4'
3
1
6'
5
1
8'
7
1
10'
9
1
12'
11
1
DISC
T-STAT
TYPE &
AIR
MODEL
MAKE
VELOC
&
EVAP &
SIZE (") &
@FPM
SETTINGS
SETTING
250
EPR
Forced 4 1/2 Axial
Air
250
EPR
Forced 4 1/2 Axial
Air
250
EPR
Forced 4 1/2 Axial
Air
250
EPR
Forced 4 1/2 Axial
Air
250
EPR
Forced 4 1/2 Axial
Air
VOLTS
PHASE
208/240
208/240
208/240
208/240
208/240
1
208/240
1
208/240
1
208/240
1
208/240
1
208/240
CIRCUIT 1
Size
VOLTS
PHASE
4'
115
6'
115
8'
208v/240V
10'
208v/240V
12'
208v/240V
CIRCUIT 1
Size
VOLTS
PHASE
4'
115
6'
115
8'
208v/240V
10'
208v/240V
12'
208v/240V

Case Specifications

FAN
DEFROST
BLADE
FREQ
CIRC. 1
&
QTY
AMPS
PITCH °
DURATION
FANS
FANS
40 min.
2
.36
(2)
(4)
40 min.
4
.72
(4)
(4)
40 min.
4
.72
(4)
(4)
40 min.
6
1.08
(6)
(4)
40 min.
6
1.08
(6)
(4)
CIRCUIT 1
Amps/ 208
240
10
11
15
17
20
23
25
28
30
34
10
11
19
22
19
22
Consult Factory
Consult Factory
Max
Load
Amps
Amps
10
-
14
-
11
12
14
16
16
18
Max
Load
Amps
Amps
10
-
14
-
11
12
14
16
16
18
NOTES:These merchandisers have been designed for use in
stores where temperatures and humidity are maintained at or
below 75°F and 55%RH. Stores are responsible for setting
their cases appropriately in conditions which vary from the
above. The number of defrosts and/or the duration may vary
for cases displaying products for which they were not
designed. Italicized data indicates optional equipment.
12
IGFP-R3H, R3HTO, R3HA, R3Combo-0208
CIRC. 3
SHELF
RECEP
Low Pressure
LEVELS
LIGHTS
TACLE Control & Setting HP
2
1.73
15.0
50 in
30 out
2
1.73
15.0
50 in
30 out
2
2.85
15.0
50 in
30 out
2
3.97
15.0
50 in
30 out
2
4.48
15.0
50 in
30 out
SELF CONTAINED INFO.
AMP-
VOLTS
ACITY
1/3
115
10.9
3/4 208~230
8.7
1 208~230 13.0
1 208~230 13.0
1 208~230 13.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

R3hatoR3haR3htoR3combo