7
These merchandisers are manufactured to meet ANSI/National Sanitation
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Specialty Products
R3TO/CR3TO
1 of 7
R3TO/CR3TO
Technical Data Sheet
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F)
24
Evaporator (F)
18
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft*
Parallel
250
Conventional
288
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs
OFFTIME
Temp Term °F
Failsafe Minutes
ELECTRIC or GAS
Not Recommended
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
Merchandiser Liquid Line (in.)
Merchandiser Suction Line (in.)
Estimated Charge (lb)***
4ft
5ft
6ft
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
GLYCOL REQUIREMENTS
GPM
PSI
NA
NA
NA
NA
NA
NA
Rev A
6
54
40
1 ½*
3/8*
5/8*
1.2
1.5
1.8

Advertisement

loading
Need help?

Need help?

Do you have a question about the Specialty Products CR3TO and is the answer not in the manual?

Questions and answers

Summary of Contents for Hussmann Specialty Products CR3TO

  • Page 1 Evaporator (F) Note: Not recommended to control temp by regulating coil temp allow t-stat to cycle and control temp. Btu/hr/ft* Parallel Conventional *For all refrigeration equipment other than Hussmann, use conventional Btu values. DEFROST DATA Frequency Hrs OFFTIME Temp Term °F...
  • Page 2 Specialty Products R3TO/CR3TO R3TO/CR3TO Technical Data Sheet Rev A Engineering Cut & Plan View R3TO/CR3TO 2 of 7...
  • Page 3 Specialty Products R3TO/CR3TO R3TO/CR3TO Technical Data Sheet Rev A 3 of 7...
  • Page 4 Specialty Products R3TO/CR3TO R3TO/CR3TO Technical Data Sheet Rev A 4 of 7...
  • Page 5 Specialty Products R3TO/CR3TO R3TO/CR3TO Technical Data Sheet Rev A 5 of 7...
  • Page 6 Specialty Products R3TO/CR3TO R3TO/CR3TO Technical Data Sheet Rev A 6 of 7...
  • Page 7 Specialty Products R3TO/CR3TO R3TO/CR3TO Technical Data Sheet Rev A 7 of 7...

This manual is also suitable for:

Specialty products r3to