Rev.0208
REFRIGERATED SECTION
BTU
REQ
TEMPERATURE
LENGTH
PER
EVAP CASE DISC
FT
TMP TMP TMP
R3P Prep Top
(Front Refrigerated Section Only)
4'
650
15° 36° 24°
6'
650
15° 36° 24°
8'
650
15° 36° 24°
10'
650
15° 36° 24°
12'
650
15° 36° 24°
R3P Prep Top with Refrigerated Rear Storage
4' Front
650
15° 36° 24°
Rear Storage 175
15° 36° 30°
6' Front
650
15° 36° 24°
Rear Storage 175
15° 36° 30°
8' Front
650
15° 36° 24°
Rear Storage 175
15° 36° 30°
10' Front
650
15° 36° 24°
Rear Storage 175
15° 36° 30°
12' Front
650
15° 36° 24°
Rear Storage 175
15° 36° 30°
R3 Service Top
(Front and Top Section - Dry Rear Storage)
4' Front
650
15° 36° 24°
Top
250
15° 36° 24°
6' Front
650
15° 36° 24°
Top
250
15° 36° 24°
8' Front
650
15° 36° 24°
Top
250
15° 36° 24°
10' Front
650
15° 36° 24°
Top
250
15° 36° 24°
12' Front
650
15° 36° 24°
Top
250
15° 36° 24°
NOTES: These refrigerated merchandisers have been designed for use in stores where temperatures and humidity are maintained at or below 75°F and 55%RH. Stores are responsible for setting
their cases appropriately in conditions which vary from the above. The number of defrosts and/or the duration may vary for cases displaying products for which they were not designed.
Italicized data indicates optional equipment.
*
In Self contained units, 4' of the Rear Storage area is occupied by the Condensing Unit
Case Specifications
DISC
T-STAT
TYPE &
FAN
AIR
MODEL
MAKE
BLADE
VELOC
&
EVAP &
SIZE (") &
PITCH °
@FPM
SETTINGS
SETTING
1
250
EPR
Forced 4
/
" Axial
2
Air
(2)
1
250
EPR
Forced 4
/
" Axial
2
Air
(4)
250
EPR
Forced 4
1
/
" Axial
2
Air
(4)
250
EPR
Forced 4
1
/
" Axial
2
Air
(6)
250
EPR
Forced 4
1
/
"Axial
2
Air
(6)
1
250
EPR
Forced 4
/
" Axial
2
Air
(2)
125
35°
Forced 5
1
/
" X 30° 40 min.
4
Air
(1)
250
EPR
Forced 4
1
/
" Axial
2
Air
(4)
125
35°
Forced 5
1
/
" X 30° 40 min.
4
Air
(1)
250
EPR
Forced 4
1
/
" Axial
2
Air
(4)
125
35°
Forced 5
1
/
"X 30°
4
Air
(2)
250
EPR
Forced 4
1
/
"Axial
2
Air
(6)
125
35°
Forced 5
1
/
" X 30° 40 min.
4
Air
(2)
1
250
EPR
Forced 4
/
" Axial
2
Air
(6)
1
125
35°
Forced 5
/
" X 30° 40 min.
4
Air
(2)
250
EPR
Forced 4
1
/
" Axial
2
Air
(2)
125
24°
Forced 3" Axial
Air
(2)
1
250
EPR
Forced 4
/
" Axial
2
Air
(4)
125
24°
Forced 3" Axial
Air
(4)
1
250
EPR
Forced 4
/
"Axial
2
Air
(4)
125
24°
Forced 3" Axial
Air
(4)
250
EPR
Forced 4
1
/
" Axial
2
Air
(6)
125
24°
Forced 3" Axial
Air
(6)
250
EPR
Forced 4
1
/
" Axial
2
Air
(6)
125
24°
Forced 3" Axial
Air
(6)
DEFROST
FREQ
CIRC. 1
&
QTY
AMPS
SHELF
DURATION
FANS
FANS
LEVELS
40 min.
2
.36
2
(4)
40 min.
4
.72
2
(4)
40 min.
4
.72
2
(4)
40 min.
6
1.08
2
(4)
40 min.
6
1.08
2
(4)
(Front Refrigerated Section)
40 min.
2
.36
2
(4)
1
1.10
2
(4)
40 min.
4
.72
2
(4)
1
1.10
2
(4)
40 min.
4
.72
2
(4)
40 min.
2
2.20
2
(4)
40 min.
6
1.08
2
(4)
2
.90
2
(4)
40 min.
6
1.08
2
(4)
2
.90
2
(4)
40 min.
2
.36
2
(4)
40 min.
2
.32
2
(4)
40 min.
4
.72
2
(4)
40 min.
4
.64
2
(4)
40 min.
4
.72
2
(4)
40 min.
4
.64
2
(4)
40 min.
6
1.08
2
(4)
40 min.
6
.96
2
(4)
40 min.
6
1.08
2
(4)
40 min.
6
.96
2
(4)
9
CIRC. 3
SELF CONTAINED INFO.*
RECEP
Low Pressure
LIGHTS
TACLE Control & Setting HP
1.73
15.0
50 in
1/3
30 out
1.73
15.0
50 in
3/4
30 out
2.85
15.0
50 in
1
30 out
3.97
15.0
50 in
1
30 out
4.48
15.0
50 in
1
30 out
1.73
15.0
50 in
1/2
30 out
1.73
15.0
1.73
15.0
50 in
3/4
30 out
1.73
15.0
2.85
15.0
50 in
1
30 out
2.85
15.0
3.97
15.0
50 in
1
1
/
30 out
3.97
15.0
1
4.48
15.0
50 in
1
/
30 out
4.48
15.0
1.73
15.0
50 in
1/2
30 out
1.73
15.0
2.24
15.0
50 in
1
30 out
2.24
15.0
3.36
15.0
50 in
1/3
30 out
3.36
15.0
5.09
15.0
50 in
1/3
30 out
5.09
15.0
5.60
15.0
5.60
15.0
AMP-
VOLTS
ACITY
115
10.9
208
8.7
~230
208
13.0
~230
208
13.0
~230
208
13.0
~230
115
19.9
208
8.7
~230
208
13.0
~230
208
19.0
2
~230
208
19.0
2
~230
115
19.9
208
13.0
~230
208
13.0
~230
208
19.0
~230