Warex DKZ 103 Installation And Maintenance Manual page 37

Industrial valves for fluids and bulk materials
Table of Contents

Advertisement

WAREX VALVE GmbH
For single and double operated actuators
Standard manual override with detent
Compact design
High flow rate
Simple design of soft spool seal system
Maintenance-free
Easily interchangeable solenoid system
Exhaust air recirculation
The solenoids are ATEX approved
(see solenoids page 2)
Valves and solenoids are ATEX approved
Technical data
Medium:
Solenoid valve for filtered, lubricated *1)
or non-lubricated air
Operation:
Solenoid, indirectly controlled
Flow direction:
Fixed
Mounting position:
Optional, preferably with solenoid on top
Nominal size:
6
Port size:
G 1/4
Electrical connection:
See solenoid table
Operating pressure:
2 to 8 bar
Temperature:
-10 ... 50°C
Please consult our technical service for use below +2°C. If installed
in the open protect all connections against the penetration of moisture!
Materials:
Housing: Aluminium
Pilot flange: Plastic
Seat seal: NBR (Perbunan)
*1) Oil recommendation: Shell Hydrol DO 32, Esso Febis (as of July 1992) or comparable
oils with DVI values < 8 (DIN 53521) and ISO viscosity class 32-46 (DIN 51519).
9/05
Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
26230, 80107 NAMUR
3/2, 4/2 and 5/2 Directional control valves
Modular NAMUR design
Actuation: electromagnetic
Indirectly controlled spool valves
Ordering information
3/2 directional control valve, connection G 1/4,
solenoid 24 V DC, protection class IP65
Part No.: 8010777.3036.024.00
Connector: 0570275
Connections
See data sheet N/UK 7.7.002
3/2
2
12
1 3
5/2
2 4
14
12
315
Port size: G 1/4
3
10
4
2
14
12
5
1
3
N/UK 5.4.302.01

Advertisement

Table of Contents
loading

Table of Contents