Warex DKZ 103 Installation And Maintenance Manual page 28

Industrial valves for fluids and bulk materials
Table of Contents

Advertisement

WAREX VALVE GmbH
AIR TORQUE
5.2) Controls and connections, Figure A :
5.3) Assembly of accessories : Solenoid valves and Switchboxes Figure B :
• Solenoid valve mounting:
Before mounting a Solenoid valve ensure that the actuator is in its normal position (closed posi-
tion) pistons together :
- For Standard assembly and rotation (Clockwise to close): the groove on the indicator 2 must be
diagonal to the longitudinal axis of the actuator in the closed position.
Fit the solenoid valve 4 onto the actuator 3 using the screws provided (max. tightening torque
see the table below).
• Switchbox mounting:
Fit the switchbox and bracket 1 onto the actuator 3, using four screws provided (max. tightening
torque see the table below).
AIR TORQUE GmbH * Im Katzentach 16-18 * D - 76275 Ettlingen
Tel.: +49-(0)7243-5934-0 * Fax: +49-(0)7243-5934-34
e-mail: info@airtorque.de * http://www.airtorque.de
The 4th Generation
Maintenance
Tightening torque table:
M..
M5
M6
M8
M10
M12
M14
M16
M20
M24
Modifications reserved. Date 02.2000.
No guarantee for accuracy.
Older data sheets are invalid.
Nm
5 -> 6
10 -> 11
23 -> 25
48 -> 52
82 -> 86
132 -> 138
200 -> 210
390 -> 410
675 -> 705