Venting Clearances - Fisher & Paykel PROFESSIONAL 9 Series Installation Manual

Black induction cooktop
Hide thumbs Also See for PROFESSIONAL 9 Series:
Table of Contents

Advertisement

DRAWER OR OTHER OBSTRUCTION
This cooktop requires adequate supply of cool air to fully function. The base of the cooktop
must have direct unrestricted ventilation to the room where the cooktop is installed. There
must be a 4mm air gap at the front of the cooktop.
A
B
Drawer or other obstruction
CLEARANCE DIMENSIONS
A Minimum ventiliation gap at the front of the cooktop
B Minimum clearance from bottom of chassis to drawer or
other obstruction
C Minimum ventiliation gap at the rear of the cooktop
D Minimum diameter of cooling air hole
10

VENTING CLEARANCES

D
C
IN
MM
CLEARANCE DIMENSIONS
3/16
4
A Minimum ventiliation gap at the front of the cooktop
B Minimum ventiliation gap at the rear of the cooktop
2 9/16
65
C Minimum diameter of cooling air hole
13/16
20
*Some ovens require installation in a sealed box. Please refer you oven installation guide for
2
50
more information.
OVEN WITH COOLING FAN
A
Oven* with cooling fan
C
B
IN
MM
3 /16
4
13/16
20
2
50