Venting Clearances - Fisher & Paykel CI304PTX Installation Manual

Black induction cooktop
Hide thumbs Also See for CI304PTX:
Table of Contents

Advertisement

DRAWER OR OTHER OBSTRUCTION
This cooktop requires adequate supply of cool air to fully function. The base of the cooktop
must have direct unrestricted ventilation to the room where the cooktop is installed. There
must be a 4mm air gap at the front of the cooktop.
A
B
Drawer or other obstruction
CLEARANCE DIMENSIONS
A Minimum ventiliation gap at the front of the cooktop
B Minimum clearance below top of countertop to top
of any appliance, companion product or obstruction
below cooktop
C Minimum ventiliation gap at the rear of the cooktop
*If ventilation gap at the rear of the cooktop is not possible, add two x 2" diameter (50mm) holes in
the side wall to allow adequate cooling air.
10

VENTING CLEARANCES

*Alternate ventilation option
C
IN
MM
3/16
4
CI304PTX
3 3/8
85
CI365PTX
3
75
13/16
20
OVEN WITH COOLING FAN
A
Oven** with cooling fan
CLEARANCE DIMENSIONS
A Minimum ventiliation gap at the front of the cooktop
B Minimum ventiliation gap at the rear of the cooktop
*If ventilation gap at the rear of the cooktop is not possible, add two x 2" diameter (50mm) holes in
the side wall to allow adequate cooling air.
**Some ovens require installation in a sealed box. Please refer you oven installation guide for
more information.
*Alternate ventilation option
B
IN
MM
3 /16
4
13/16
20