section 6. Vacuuming to Waste
(Optional)
nOTE: To ensure that water will not return to the pool or spa
during the "vacuum to waste" operation, a valve is
required on the return line to the pool. See Figure 5.
Close this valve or for Jandy Pro Series valves, loosen
the locking knob and ensure the valve stop is facing
the filter return line.
1.
Ensure that the pump is OFF (not running and not
likely to turn on in "timed filter" or "heat demand"
mode).
2.
Close valve on return line or Jandy Pro Series
valve. See Note above.
3.
Loosen locking knob on the NeverLube
valve handle.
4.
While turning clockwise, lift the valve handle to
clear the handle stop on the valve cover. Then
align the handle to the WAsTE position on the
valve cover. This closes the inlet and outlet ports
of the filter.
5.
Connect vacuuming hose to pool skimmer or the
sweep inlet line. Turn on pump and vacuum as
desired.
6.
After vacuuming to waste, turn off pump, remove
vacuuming hose, and return both valves to their
normal operating position. Check that controls are
once again set for normal operations.
Jandy
Pro Series, NeverLube
Backwash Valve
®
®
Filter
Pump
backwash
Figure 5.
|
Installation & Operation Manual
Three-way Valve
(valve stop towards filter
during vacuum operation)
Pool
Spa
Pool Return
(Top Port)
Pump Inlet
(Bottom Port)
To
Waste
Vacuuming to Waste
Filter
NeverLube
Backwash Valve