section 3. Versa-Coupler
installation
1.
There is an alignment mark on each versa-coupler
and four (4) alignment marks on the NeverLube
backwash valve port faces. See Figure 4.
2.
Slide a versa-coupler into the TO FILTER
INLET and the FROM FILTER OUTLET
ports on the NeverLube backwash valve.
nOTE: Certain filters require two (2) p/n 8044 versa- couplers.
3.
Hold the NeverLube backwash valve up to the
filter and twist the versa-couplers until they slide
into the filter inlet and outlet ports. Tighten the
filter union nuts.
nOTE: Make sure to align each versa-coupler to the filter
and NeverLube backwash valve prior to gluing the
assembly.
4.
If the alignment marks don't line up, make a mark
on the coupler and valve for reassembly.
5.
Remove the valve from the filter. Clean the
couplers and glue them onto the valve using the
alignment marks as a reference.
6.
Clean the versa-coupler(s) and glue it onto the
filter, matching the valve port marked TO FILTER
INLET with the filter inlet. Hold the coupler in
place for a minimum of one (1) minute.
7.
Plumb the FROM PUMP, POOL RETURN,
and WASTE ports as needed. Let the system dry
for 24 hours.
8.
When the glue is dry, start the system and check
for proper water flow.
9.
After the glue has dried, flush the system by
setting the valve to BACKWASH. Start filter
pump(s). Run the system until the waste water is
clean. Turn off the filter pump(s) and set the valve
to FILTER.

section 4. normal Operation

1.
Make sure the valve handle is pointing towards
FILTER.
2.
Turn on the filter pump(s). Check the system for
normal water flow.
|
Backwash Valve
Installation & Operation Manual
®

section 5. Backwashing

iMPORTAnT nOTE: Be sure to follow any and all applicable
English
WARning
never attempt to assemble,
disassemble or adjust the filter when
there is pressurized air in the system.
Starting the pump while there is
any pressurized air in the system
can cause the filter lid to be blown
off, which can cause death, serious
personal injury or property damage.
1.
Turn off all system pump(s).
2.
Open the pressure relief valve on top of the filter.
Wait for all the air to evacuate the system.
3.
Loosen the handle locking knob and turn the
valve handle to the BACKWASH position.
Tighten the locking knob.
4.
Turn on the system pump(s) and run the system
until the waste water runs clean.
local codes related to proper discharge/drainage of
water from your pool/spa.
5.
Close pressure relief valve when water comes out
at valve.
6.
Turn off all system pump(s).
7.
Return the valve handle to the FILTER position.
Tighten the locking knob.
8.
Turn on system pump(s) and check for normal
water flow.