Remote control

Modes of control

Note Every command sent from the remote to the awning blind is
preceded with the period of awakening the blind. It lasts about 0.3
sec. In practice it reflects in 0.5 sec. delay of the awning blind.
The awning blind can be controlled in one of three modes:
1 ) manual – control with the use of the remote control
2) semi-automatic – automatic closing and with the use of the remote control
3) automatic – automatic opening and closing and with the use of the remote
control
In the automatic control mode the awning blind is controlled by the
actuator on the basis of predetermined algorithm. In this mode the blind
can also be manually operated, but after expiration of set time (default
3min.) the actuator takes control over the awning blind operation.
In semi-automatic mode due to exceeding set value of insolation
level the awning blind unrolls. Rolling up is possible only with the remote
control. After manual rolling up of the awning blind due to the exceeding
set value of solar insolation and after expiration of set time, the actuator
one more time unrolls the awning blind.
In manual mode the awning blind can be controlled only via the
remote control (automatic control is turned off).
Switching between control modes
Switching between control modes is made via remote control
(buttons M S A) or automatically depending on the voltage level of
terminals of the charged battery. Below 1 2,3V there is a change from
automatic to manual mode. In manual mode below 11 ,8 V the awning
blind cannot be unrolled. It is signalled through its downward movement
(about 3cm) and upward. The awning blind will be stopped in case of
voltage below 11 ,1 V in order to protect the battery.

Procedure for selection of mode control:

1 . Channel selection (with SELECT button) from four available to which
the device is programmed.
2. Choice of the mode control: M – manual, S – semi-automatic or A –
automatic.