201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR
5. Do not over-choke. As soon as engine starts, turn the EZ
Start dial to the "RUN" position.
Warm Engine Start
3. Turn the EZ Start dial to the "RUN" position.
4. Press and hold the yellow ignition switch on the EZ Start Dial
toward the center of the dial. Release as the engine begins to
start. If the engine fails to start within five seconds, release
the switch and wait at least ten seconds before attempting to
start the engine again.
If the engine starts but does not continue to run, make certain
that the generator is on a flat, level surface. The engine is
equipped with a low oil sensor that will prevent the engine
from running when the oil level falls below a critical threshold.
NOTICE

Starting the Engine: Propane (LPG)

Turn the generator off before attempting to switch from
gasoline to LPG operation.
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Open the fuel valve on the propane cylinder.
Manual Start
Cold Engine Start
4. Move the EZ Start dial to the "CHOKE" position.
5. Slowly pull the starter cord 2-3 times to prime the engine.
26
OPERATION
NOTICE