Champion 201080 Operator's Manual page 23

4650w dual fuel electric start inverter generator
Table of Contents

Advertisement

201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR
AUTOMATIC
AUTOMATIC
SHUTOFF
SHUTOFF
SEE ACTION
SEE ACTION
LABEL
LABEL
ARRÊT
ARRÊT
AUTOMATIQUE
AUTOMATIQUE
VOIR L'ÉTIQUETTE
VOIR L'ÉTIQUETTE
D'ACTION
D'ACTION
Move the generator far away to an open, outdoor area and point
the exhaust away from people and buildings. Once relocated
to a safe area, the generator can be restarted, and the proper
electrical connections made. Introduce fresh air and ventilate the
location where the generator shut off.
When restarting, the red and yellow LED will blink ten (10) times
simultaneously to indicate the LED is working.
This blinking LED light does not indicate CO Shield
as CO Shield
is working at all times when the generator
®
is running. Also, the LED light will not blink (10) times if the
generator was restarted within 1 minute after it was manually
shut off. This does not occur if generator shut off from a high
CO event.
If CO Shield
system experiences a fault and no longer provides
®
protection, the generator is shutoff automatically and the yellow
LED light will blink for at least five (5) minutes to notify you of the
fault.
AUTOMATIC
AUTOMATIC
SHUTOFF
SHUTOFF
SEE ACTION
SEE ACTION
LABEL
LABEL
ARRÊT
ARRÊT
AUTOMATIQUE
AUTOMATIQUE
VOIR L'ÉTIQUETTE
VOIR L'ÉTIQUETTE
D'ACTION
D'ACTION
Call our Technical Support Team at 1-877-338-0999 for repair.
The generator can be restarted, but will continue to shutoff.
ECO
SERVICE
SERVICE
EFFECTUER
EFFECTUER
L'ENTRETIEN
L'ENTRETIEN
NOTICE
is working,
®
ECO
SERVICE
SERVICE
EFFECTUER
EFFECTUER
L'ENTRETIEN
L'ENTRETIEN
CO Shield
will detect the accumulation of carbon monoxide
®
(CO) from other fuel burning sources such as engine powered
equipment, or propane heaters used in the area of operation. If
another generator is used and the exhaust stream is pointed at
a CO Shield
equipped generator, the CO Shield
®
a shutoff due to rising carbon monoxide (CO) levels. This is not
a fault. Poisonous carbon monoxide (CO) has been detected.
You must take action to move and direct the generator exhaust
stream to better disperse carbon monoxide (CO) far away from
people or buildings.
Tampering with the CO Shield
hazardous condition and will void your warranty.
Removing the CO Shield
to start.
23
OPERATION
NOTICE
may initiate
®
DANGER
system will result in a
®
module will not allow the generator
®

Advertisement

Table of Contents
loading

Table of Contents