4 - Battery pack harness
CAUTION:
The battery is a lithium ion battery. To avoid possible explosion, do not
burn. Exchange only with the IBM-approved part. Recycle or discard the
battery as instructed by local regulations. In the United States, IBM has a
process for the collection of this battery. For information, call 1-800-426-
4333. Have the IBM part number for the battery unit available when you
call. (C007)
If the ServeRAID-MR10M controller is already installed in a computer,
follow these steps to remove it before you install the iBBU:
1. Shut down the computer, turn off the power, and unplug the power
cords.
2. Remove the cover from the computer according to the instructions in
the system user's manual so you can access the controller.
3. Ground yourself before you touch the controller.
4. Unplug all cables from the controller, remove the screw attaching the
bracket to the computer case, and carefully remove the controller
from the slot.
5. Place the controller on a flat, clean, static-free surface, and continue
with the next section.
Perform the following steps to mount the iBBU directly to the ServeRAID-
MR10M controller using the daughtercard. (All components are installed
on the bottom of the card. The battery is installed on the top. The
maximum height of components installed on the iBBU is 0.125".)
1. Ground yourself, and remove the iBBU daughtercard from the
package.
2. Insert the battery pack harness into the 5-pin J4 connector on the
bottom of the iBBU.
3. Hold the iBBU daughtercard so that the battery side is up and the J5
connector lines up with the J1 iBBU connector on the controller, as
shown in
Figure
Installing the iBBU on the ServeRAID-MR10M Controller
5.2.
5-3