1. If fitting an existing valve with an actuator
remove existing handle and install the lock tab
and half nut.
3. Use pliers and crush the lock tab onto
the nut.
We reserve the right to modify product specifications without prior notice.
We reserve the right to modify product specifications without prior notice.
If valve not supplied with actuator or bracket follow these instructions
2. Tighten the half nut to the required
torque.
Stem nut tightening torque
BV703 = 3Nm
BV704 = 3Nm
BV706 = 6Nm
BV708 = 6Nm
4. Insert the ball valve into the actuator
mount so that the stop pin goes in first.
3
Installation
Instructions
BV700-INS-03 2822 © Oasis Engineering Limited
BV700-INS-03 2822 © Oasis Engineering Limited