Download Print this page

Operation - Oasis BV700 Series Instruction Manual

Actuated ball valve npt
Hide thumbs Also See for BV700 Series:

Advertisement

1. Connect air line and check connections for leaks.
For oasis standard actuators the
left port is the inlet port used to
activate the actuator.
MAX 8 Bar
Do not operate the actuator
with supply pressure greater
than 8 Bar (116 psi). Doing so
may damage the actuator and
void the warranty.
Recommended Spanners
for End Caps:
BV702 = 25mm
BV703 = 28mm
BV704 = 34mm
BV706 = 50mm
BV708 = 60mm
We reserve the right to modify product specifications without prior notice.
Check connections for leaks using
snoop or soapy water.
8
BV700-INS-03 2822 © Oasis Engineering Limited

Operation

Instructions