Page 1
Oasis products must be installed, operated and maintained by trained and competent personnel in accordance with all applicable local codes, rules and regulations in addition to the Oasis Instructions. Oasis Engineering Ltd. will not be held liable in such circumstances where installation, operation and maintenance procedures were performed by incompetent personnel resulting in improper assembly, unsafe operation, equipment damage or personal injury.
Page 2
High pressure gas and gas equipment can cause serious harm to both infrastructure and personnel if safety precautions are not followed. Oasis recommends considering the use of the following PPE when working with high pressure along with any other site specific health and safety requirements:...
Installation Instructions Important Oasis recommends the use of class 12.9 plain black socket head cap screws with this product. Some surface corrosion is normal on plain black cap screws over time. The use of zinc plated cap screws is NOT recommended by...
* only used when servicing actuated ball valves. ** It is normal for the service kit to include a ball with a small hole in the bottom The Complete Oasis Seal Kit must be used Hex End Cap Sizes (A/F) Stem Nuts Sizes (A/F)
Page 9
Servicing - Disassembly SV103 SV104 - SV106 - SV108 7. Remove 2nd seat and discard. 7. Remove stem. Do not scratch body 8. Remove stem and discard. 8. Remove 2nd seat and discard. Do not scratch body 9. Clean components and inspect for damage.
Page 10
Servicing - Assembly SV104 - SV106 - SV108 SV103 1. Insert stem assembly first. 1. Insert seat first. Click 2. Insert seat. 2. Insert stem assembly. Click 3. Insert ball. We reserve the right to modify product specifications without prior notice.
Need help?
Do you have a question about the SV104 and is the answer not in the manual?
Questions and answers