H3DE-F
Characteristics
Accuracy of operating
time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
EMC
Enclosure rating
Weight
Note: For reference:
A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
16
1% max. of FS ( 1% 10 ms max. at 1.2-s range)
10%
0.05 s max. of FS
0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range)
2% max. of FS ( 2%
10 ms max. at 1.2-s range)
100 MΩ min. at 500 VDC
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60
Hz) for 1 min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) 1.5 kV
Malfunction: 4 kV
Destruction: 8 kV
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
2
Malfunction: 100 m/s
(approximately 10G)
2
Destruction: 1,000 m/s
(approximately 100G)
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
(EMI):
Emission Enclosure:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuation and Flickering:
(EMS):
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance:
Immunity Burst:
IP30 (IP20 for terminal block)
Approx. 110 g
EN50081-1
EN55022 class B
EN55022 class B
EN61000-3-2
EN61000-3-3
EN50082-2
EN61000-4-2:4 kV contact discharge (level 2)
8 kV air discharge (level 3)
ENV50140: 10 V/m (80 MHz and 1 GHz) (level 3)
ENV50204: 10 V/m (900 5 MHz) (level 3)
ENV50141: 10 V (0.15 to 80 MHz) (level 3)
EN61000-4-4:2 kV power line (level 3)
2 kV I/O signal line (level 4)