Additional Settings For Weekly Timer; Other Functions; Switching The Key Sound On/Off; Turbo Cool/Turbo Heat - Bosch Climate 5000 L Operating Instructions For Users

Large split air conditioner
Hide thumbs Also See for Climate 5000 L:
Table of Contents

Advertisement

Operation
3.8.4

Additional settings for weekly timer

Provisionally disabling the timer
To disable the timer on selected days only:
▶ Press the TIMER key until WEEK 1 or WEEK 2 appears in the display.
▶ Press the  key.
▶ Press the . or / key to select the weekday.
▶ Press the DAY OFF key.
The selected day is no longer displayed.
The timer is deactivated for the days that are not displayed until the day
has passed.
▶ Press the DAY OFF key again to display the day once again.
▶ Repeat the above if necessary for the other days.
Adopting (copying) settings from one day to another day
▶ Press the TIMER key until WEEK 1 or WEEK 2 appears in the display.
▶ Press the  key.
▶ Press the . or / key to select the day whose settings should be
adopted.
▶ Press the COPY key to copy the settings.
CY appears on the display.
▶ Press the . or / key to select the day to which the settings should
be copied.
▶ Press the COPY key to insert the copied settings.
The selected weekday flashes briefly as confirmation.
▶ Repeat the above steps if necessary to copy the information to other
days.
▶ Press the  key to adopt the changes.
3.9

Other functions

3.9.1

Switching the key sound on/off

To switch the the key sound of the wired room controller on or off:
▶ Press and hold the
and FUNC. keys for three seconds.
3.9.2

Turbo cool/Turbo heat

When Turbo cool/Turbo heat is active, the indoor unit operates at
maximum power to heat or cool the room quickly.
Turbo Cool:
▶ Switch on cooling mode.
▶ Press the FUNC. key.
▶ Confirm with  key.
Turbo Heat:
▶ Switch on heating mode.
▶ Press the FUNC. key.
▶ Confirm with  key.
Exiting the function:
▶ Press the FUNC. key again.
▶ Confirm with  key.
3.9.3

Noise reduction (Silent Mode)

This function reduces the noises emitted by the indoor and outdoor unit
when it is in operation. This is particularly advantageous at night, if you
need to show consideration for your neighbours.
▶ During operation, press the
Exiting the function:
▶ Press the
key again for 2 seconds.
-or-
▶ Press the K key, Mode key, Turbo key or Clean key.
42
key for 2 seconds.
When the outdoor unit is in quiet mode, it may not be possible to achieve
the required cooling/heating capacity because the compressor operates
at a low frequency.
3.9.4

Self-cleaning (I clean)

The device has a self-cleaning function for the evaporator. The self-
cleaning freezes dust, mould and grease. Everything is then quickly
defrosted and dried with hot air.
▶ To activate the self-cleaning: press the Clean key.
CL appears on the display of the indoor unit when self-cleaning is in
progress. Self-cleaning ends automatically after 20 to 45 minutes.
3.9.5

Sleep mode

The purpose of this function is to save energy during idle times. After an
hour, the device heats or cools less intensely. To do this, the set
temperature is changed by 1 °C. After two hours, the set temperature
changes by a further 1 °C. Then it remains at the new temperature.
The function is not available in dehumidification mode and Fan Mode.
3.9.6

Wireless control function

The purpose of this function is to establish a connection via WLAN.
To connect to WLAN an IP-Gateway (optional accessory) must be
installed.
NOTICE
For TWIN installation, an IP gateway is sufficient for the master unit. No
gateway is required for the slave unit.
3.9.7

Keylock

The keys of the wired room controller can be locked with the keylock.
To switch the keylock on or off:
▶ Press/keep the TIMER and COPY keys pressed simultaneously for
three seconds.
The symbol
appears in the display when the keylock is active.
3.9.8

Follow me function (Follow Me)

This function activates the temperature sensor of the wired room
controller. The room temperature is measured at the position of the
wired room controller instead of at the indoor unit.
▶ Switch off heating or cooling mode if required.
▶ Press the FUNC. key to switch the function on or off.
When the function is active the wired room unit displays the
symbol.
▶ Confirm with  key.
Climate 5000 L • Climate 5000i U/L – 6721841496 (2021/10)

Advertisement

Table of Contents
loading

Table of Contents