Factory Default Parameter; Repeater Networking Mode - Ebyte E22-400T33S User Manual

Sx1262 433/470mhz 2w lora wireless module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.

7.3 Factory default parameter

Model No.
Frequency
410.125~
E22-400T33S
493.125MHz

8 Repeater networking mode

No.
1
After setting the repeater mode by configuration, switch to the normal mode and the repeater starts working.
In the repeater mode, ADDH, ADDL are no longer used as the module address, but is correspondingly paired with the NETID. If
2
the data of one of the networks is received, it is forwarded to another network. The network ID of the repeater itself is invalid.
3
In repeater mode, the repeater module cannot transmit and receive data, and cannot perform low-power operation.
The user enters the other mode from mode 3 (sleep mode) or during the reset process, the module resets the user parameters
4
during which the AUX outputs low level.
Repeater networking rules:
1. Forwarding rules, the repeater can forward data in both directions between two NETIDs.
2. In repeater mode, ADDH\ADDL is no longer used as the module address, and it is used as a NETID forwarding pairing flag.
Figure:
Primary repeater
1
"Node 1" NETID is 08.
"Node 2" NETID is 33.
Primary repeater 1's 'ADDH\ADDL are 08,33.
So the signal sent by node 1 (08) can be forwarded to node 2 (33)
At the same time, node 1 and node 2 have the same address, so the data transmitted by node 1 can be received by node 2.
② Secondary repeater
Secondary repeater's ADDH\ADDL are 33,05.
Therefore, Repeater 2 can forward the data of Repeater 1 to the network NETID: 05.
Thus node 3 and node 4 can receive node 1 data. Node 4 outputs data normally, and node 3 has a different address than node 1, so no
data is output.
Two-way repeater
3
As shown in the figure: the data sent by node 1, the nodes 2, 4 can receive the data sent by node 2, 4, and node 1 can also receive
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
Factory default parameters:C0 00 00 62 00 17
Address
Channel
0x0000
0x17
Air data rate
Baud rate
2.4kbps
9600
Description
E22-400T33S User Manual
Parity format
Power
8N1
33dbm