Command Format; Default Parameter Values; Reading Operating Parameters; Reading Version Number - Ebyte E28-2G4T27SX User Manual

Sx1280 2.4ghz lora module
Hide thumbs Also See for E28-2G4T27SX:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.

7. Command Format

Under configuration mode (Mode 3:M0=1, M1=1, M2 =1), the supported parameters are as below
(Only support 9600 and 8N1 format when setting)
Command
No.
Format
C0 + working
1
parameters
C1+C1+C1
2
C2 + working
3
parameters
4
C3+C3+C3
5
C4+C4+C4
6
E2+E2+E2
7
E3+E3+E3
7.1.

Default parameter values

Model
Model
Frequency
E28-2G4T27SX
2.4GHz
7.2.

Reading Operating Parameters

Command Format
C1+C1+C1
7.3.

Reading Version Number

Command Format
C3+C3+C3
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must be sent in
succession.
(Save the parameters when power-down)
Three C1 are sent in hexadecimal format. The module returns the saved parameters and must be sent in
succession.
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must be sent in
succession. (Do not save the parameters when power-down)
Three C3 are sent in hexadecimal format. The module returns the version information and they must be
sent in succession.
Three C4 are sent in hexadecimal format. The module will reset one time and they must be sent in
succession.
Under transparent transmission mode, send three E2 in HEX format, the module will enter a 10s
parameter configuration window period, user could configure the module parameters in the 10s with C0
command, 10s later, the module will work with the new parameters.
Under transparent transmission mode, send three E3 in HEX format, the module will enter a 10s
parameter configuration window period, user could configure the module parameters in the 10s with
6-byte C0 command, 10s later, the module will work with the new parameters.
Address
Channel
0x0000
0x13
Under configuration,(M0=1,M1=1), send command (HEX format) to the serial: C1 C1 C1, the
module will return current parameter values, i.e.:
Under configuration mode (M0=0, M1=1, M2 =0), send command (HEX format) to the serial:
C3 C3 C3, the module will return current parameter values, i.e.: C3 00 28 10 0C 09 01 00;
The 00 28 means the module model number (E28 series), 10 means the version number, 0C
means the transmitting power, other values means other characteristics.
Description
Default parameter values:
Air data rate
Baud rate
10kbps
Description
C0 00 00 13 18 04
Description
E28-2G4T27SX User Manual
Transmitting
Parity
9600
8N1
.
power
27dbm
11

Advertisement

Table of Contents
loading

Table of Contents