Chassis Id Leds - Cisco SFS 7008 Hardware Manual

Infiniband server switch
Table of Contents

Advertisement

74
Table 5-10: Interpreting the Power Supply Status LEDs (see
Color
State
Green over Yellow
off
Green
solid on
Green
off
Yellow
solid on
Master Management Connection Status LED
The Master Management Connection Status LED is a single LED that indicates whether that particular
Management Interface module is connected to the system's active master controller.
Refer to
Figure 5-5
to view the location of this LED.
Table 5-11: Interpreting the Master Management Connection LEDs (see
Color
State
Green
off
Green
solid on
Ethernet Management Port RJ-45 connector LEDs
Refer to
Figure 5-5
to view the location of this LED.
Table 5-12: Interpreting the Ethernet Management Port LEDs (see
Location
State
Left port LED
off
Left port LED
on
Right port LED
off
Right port LED
on

Chassis ID LEDs

Figure 5-7: Chassis ID LEDs
The Chassis ID Status LED indicates the status of this module.
Indication
No fan module installed, or LED failure.
Power supply is running with no errors detected.
No power to the Power supply, LED failure, or yellow LED is
On.
Failure of the Power Supply. Operator attention required.
The "!" label indicates a failure.
Indication
Management module is not connected to the active master
controller, or is connected to the system's standby master
controller.
Management module is connected to the system's active master
controller.
Indication
Port is not connected or logical link is down.
Port is connected and logical link is up.
No traffic is moving on the Ethernet Management port link.
Logical link may or may not be Up.
Traffic is moving on the Ethernet Management port link.
Figure
5-6)
Figure
5-6)
Figure
5-6)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Topspin 270