Run Power Supply Tests; Run A Led Test On The Power Supply - Cisco SFS 7008 Hardware Manual

Infiniband server switch
Table of Contents

Advertisement

96
Topspin-270# show diag fru-error
============================================================
============================================================
fru-slot
------------------------------------------------------------
card(1)
card(2)
card(7)
card(8)
card(9)
card(10)
card(11)
card(12)
card(13)
card(14)
card(15)
card(17)
fan(1)
fan(2)
Topspin-270# reload
System configuration is modified. Save? [yes(default) | no | filename] y
Proceed with reload? [yes(default) | no] y

Run Power Supply Tests

Topspin-270> enable
Topspin-270# config
Topspin-270(config)# diag power-supply 1
Topspin-270(config-diag-power-supply-1)# test led
Topspin-270(config-diag-power-supply-1)# start
Topspin-270(config-diag-power-supply-1)# stop
Topspin-270(config-diag-power-supply-1)#
4.
Use the show diag fru-error command to display any errors that appear in the result-string.
Example
fru-error
none
none
none
none
none
none
none
none
none
none
none
none
none
none
5.
Reboot the chassis when the self-test is complete.
Example
The following tests are available to locate and diagnose fan modules:
LED
page 96
Self-Test
page 97

Run a LED Test on the Power Supply

Use the LED test to blink the LED and identify a specific power supply.
Example
Fru-Error

Advertisement

Table of Contents