Topspin-270# show power-supply
=====================================================================
=====================================================================
ps
type
admin-status
---------------------------------------------------------------------
1
AC
up
2
AC
up
Topspin-270> enable
Topspin-270# config
Topspin-270(config)# diag power-supply 2
Topspin-270(config-diag-power-supply-2)# test self-test
Topspin-270(config-diag-power-supply-2)# start
Topspin-270(config-diag-power-supply-2)# exit
Topspin-270(config)# exit
Topspin-270# show diag power-supply
================================================================================
================================================================================
module-type : power-supply
module-number : 2
iterations : 1
percentage-completed : 100
result-string : Self Test, Final report : PASSED; Please reboot syst
em
Topspin-270#

Run a Self-Test on a Power Supply

1.
Show the ID of the power supply that you want to diagnose, if you do not already know the
number.
a.
Enter the show power-supply command.
Example
Power-supply Information
oper-status
up
up
2.
Enter the diag power-supply <id> command and specify the type of test (self-test is chosen by
default).
Example
3.
Start the test.
Example
4.
Use the show diag fan command to show the progress of the test.
Example
Diagnostic Tests For Power Supply
test : self-test
action : start
result : success
utilization
voltage
n/a
48
15
47
97

Advertisement