The power supplies are 1U, 48V, 1200W
The supplies provide regulated +48V DC to all other modules in the system.
Each power supply has self contained fans for cooling.

Fan Trays

Refer to
"Installing a Fan Module" on page 41
The fan trays are redundant, hot-swappable cooling units.
Only one fan tray, in either of the two slots, is required to cool the system. However, a blanking
panel is required for any unused bay.
The replacement of any one fan tray does not disrupt the operation of the device in any way, and
can be successfully completed without having to remove the device from a rack, or disconnect any
cables.
The fan modules use DC Voltage regulators to control fan speed and contain a hardware fan control
circuit, which controls and monitors the fan speed.
The fan module will default to full speed after a power-on or reset condition.
If one the fans fails, the redundant fan will go to full speed (if one is available).
CAUTION: The fan modules do not have guards. Do not remove a fan module completely from the
bay until the blades have stopped moving (approximately 15 seconds).

Management Interface Modules

See
Figure 1-2 on page 14
Refer to
"Installing a Management Interface Module" on page 50
The Topspin 270 supports redundant, hot-swappable Management Interface modules, each of which is
paired to one of the Fabric Controller Core modules.
The Management Interface modules provide the following functions:
RS-232 serial console port
10/100 Ethernet management port
System real time clock (RTC)
Intra-system Ethernet switch, which provides a system configuration management data-path to all
fabric modules.
Provide mirrors of the LED indicators from the front side of the chassis for the power supply, fans,
and over-all system status. (refer to
Rack Alarm Connection (refer to
Ethernet
Redundant
Port
LEDs
Figure 1-5: Management Interface Module
for installation instructions.
for a diagram of the chassis.
"Management Interface Module LEDs" on page
"Rack Alarm" on page
Rack Alarm
Serial
(not supported)
Port
for installation instructions.
19).
17
71).