Connect the other ends of the terminal block cables to the site ground connection. Move the circuit-breaker switch to
Step 8
the On position (|).
This completes the procedure for connecting DC-input power. Your installation is complete. Proceed to the
section on page 14
to start the router.
After powering off the router, wait a minimum of 30 seconds before powering it on again.
Note

Verifying Power Supply Operation

Follow this procedure to verify power supply is operating correctly.
Check that the power supply LEDs are:
Step 1
• INPUT OK is green
• FAN OK is green
• OUTPUT FAILED is not illuminated
Step 2
To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco
ASR1004 router. The other Cisco ASR1000 routers display similar type of output.
MCP_SCAL_R1#sho plat
Chassis type: ASR1004
The following output displays:
Slot
Type
1
ASR1000-SIP10
1/1
SPA-8X1GE-V2
2
ASR1000-SIP10
2/0
SPA-1X10GE-L-V2 ok
2/1
SPA-8X1GE-V2
R0
ASR1000-RP1
F0
ASR1000-ESP20
P0
ASR1004-PWR-AC
P1
ASR1004-PWR-AC
Slot
CPLD Version
1
07091401
2
07091401
R0
08060301
F0
08041102
MCP_SCAL_R1#
If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for
assistance or additional instructions.
20
State
Insert Time
ok
00:03:19
ok
00:02:23
ok
00:03:19
00:02:22
ok
00:02:17
ok,active 00:03:19
ok,active 00:03:19
ok
00:02:50
ps, fail
00:02:50
Firmware
Version
12.2(33r)XN2
12.2(33r)XN2
12.2(0:0)
12.2(33r)XN2