12 Inch LED Inset Runway Edge Light with Circular Guidance Instruction Manual Airfield Lighting Systems UK Limited Aviation House, Russell Gardens, Wickford Essex SS11 8BF Tel +44 1702 547866 sales@alsukltd.co.uk www.alsukltd.co.uk...
Page 2
Unintended uses, includes the following actions: Making changes to equipment that have not been recommended or described in this manual or using parts that are not genuine ALS replacement parts or accessories. Failing to make sure that auxiliary equipment complies with approval agency requirements, local codes, and all applicable safety standards.
Page 3
ALS to notify any person of such revision or change. Details and values given in this manual are average values. They are not binding, however, and ALS disclaims any liability for damages or detriments suffered as a result of reliance on the information given herein or the use of products, processes or equipment to which this manual refers.
Table of Contents Safety ..........................1 1.1. Safety Symbols ....................1 1.2. Professional ....................... 1 1.3. Introduction to safety ..................2 Equipment Information ....................4 2.1. Fixtures in this manual ..................4 2.2. Compliance with standards ................6 2.3. Features ......................6 2.4.
1. Safety This section contains general safety instructions for installing and using ALS equipment. 1.1. Safety Symbols Carefully read and observe all safety instructions in this manual, which alert you to safety hazards and conditions that may result in personal injury, death or property and equipment damage and are accompanied by the symbol shown below.
1.3. Introduction to safety WARNING This equipment may contain electrostatic devices and hazardous voltages. • Read installation instructions in their entirety before starting installation. • Become familiar with the general safety instructions in this section of the manual before installing, operating, maintaining or repairing this equipment. •...
Page 7
• Do not operate a system that contains malfunctioning components. If a component malfunctions, turn the system OFF immediately. • Allow only qualified personnel to make repairs. Repair or replace the malfunctioning component according to instructions provided in its manual. •...
2. Equipment Information 2.1. Fixtures in this manual This manual covers the following 12-inch fixtures: Light Fixture Ordering Code Optical Toe-in Color Sketch Runway Edge Light RB/IN-WW(L) - (width of runway Toe-in 3.5° White, White is 45m) Runway Edge Light RB/IN-WW(L) - (width of runway Toe-in 4.5°...
Page 9
Runway Edge Light (width of runway RB/IN-RW(L) -C Toe-in 4.5° Red ,White, is 60m) Runway Edge Light (width of runway RB/IN-WY(L) -C Toe-in 3.5° White, Yellow is 45m) RunwayEdge Light (width of runway RB/IN-WY(L) -C Toe-in 4.5° White, Yellow is 60m) Runway Edge Light (width of runway RB/IN-YW(L)-C...
2.5. Dimensions and Weight 6-φ11 Packing Data Airfield Lighting Systems UK Limited Aviation House, Russell Gardens, Wickford Essex SS11 8BF Tel +44 1702 547866 sales@alsukltd.co.uk www.alsukltd.co.uk...
3. Installation 3.1. Tools and Material Spanner 17 mm Torque wrench with a 16/17 mm socket Brush or cloth Six M10×25 bolts Sixφ10 Locking washers 3.2. Installation steps The installation process of light fixtures includes locating installation holes on the pavement, wiring, base embedding and mounting of lights.
Page 14
The letter indicates the light color of this window: W-White, R-Red, Y-Yellow The arrow indicates the toe-in direction of the main beam (the figure on the right indicates toe-in left). No arrow indicates no toe-in. Installation Steps 1-12-in shallow base 2-light fixture 3-Ø10 lock-washers 4-M10×30 bolt...
7. In order to bond the light fixture to ground, use the The grounding point supplied screw to attach the braided ground strap to the grounding point on the light fixture. The grounding point is indicated by a grounding symbol and located on the bottom side.
Page 16
Step3: Increase the torque to 17.9 Nm. (Use GTP600 lubricant to 22 Nm.) following the pattern shown below. Step4: Increase the torque to 26.9 Nm. (Use GTP600 lubricant to 33 Nm.) following the pattern shown below. Step5: Perform one final pass on each bolt working clockwise from bolt 1, at 26.9 Nm. (Use GTP600 lubricant at 33 Nm.)...
4. Maintenance This section describes the steps of lamp maintenance. Be sure to read and understand the safety instructions before starting maintenance. If a new lamp is used to replace an existing lamp, it is necessary to confirm whether the lamp model is correct through the label at the bottom of the lamp before replacement.
Monthly Check of the optical window, check for mechanical damage. Check for proper fixing of the light fixture in its base. Yearly Detailed inspection of the light fixture. Check of the body resistance, check for mechanical damage (for example cracks around prism windows). Clean of the optical windows.
4.2.2 Remove a light fixture from its base Use a torque socket wrench to remove the M10×30 bolts, spring washer and flat washer. 2. Pry up the lighting fixture with the 8 inches lighting fixture pry bar. After the light fixture and base are separated, vertically lift the light fixture with the light fixture handle and dismount the ground lead with the cross screwdriver, then disconnect the secondary cable connectors.
4.2.3 Remove and replace light source 1. Place the light fixture upside down, remove the six m5 × 16 hexagon screws, and separate the upper cover from the bottom cover (if the upper cover and the bottom cover are adhered too tightly, pry it open with the help of a large slotted screwdriver).
4.2.4 Replace the prism and its sealing gasket 1. Place the light fixture upside down, remove the six m5 × 16 hexagon screws, and separate the upper cover from the bottom cover (if the upper cover and the bottom cover are adhered too tightly, pry it open with the help of a large slotted screwdriver).
4.2.5 Waterproof test Prepare 1. Remove the gas valve cap at the bottom of the light. 2. Use air compressor to inject air into the lamp (the test air pressure shall not be less than 130kpa). Test 1. Put the light fixture in water, keep the water level above the lamp, wait 3 minutes and observe if air leaks out of the light fixture.
5. Spare Parts The table in this chapter lists the components, spare articles and accessories of this product and relevant ordering information. Spare articles and accessories of this product needs to be ordered additionally, and the manufacturer accepts the order in assembly mode and separate order of components.
Page 24
BC-12-II-WW Used for RB/IN-WW(L) (2 plugs) Used for RB/IN-WR(L), RB/IN-RW(L), RB/IN- BC-12-II-CW WY(L) or RB/IN-YW(L) (2 plugs) Used for RB/IN-YR(L) or RB/IN-RY(L) (2 BC-12-II-CC plugs) 1- Upper cover 2-Circuit board 3-Upper cover gasket 4-Prism gasket-1 5-Prism gasket-2 6-Prism-1 7-Prism-2 8-Plastic cushion 9-LED assembly-1 10-LED assembly-2 11-Bottom cover...
Need help?