Maintenance; Preventive Maintenance Schedule - Atlas Copco MAS 200 Instruction Book

Table of Contents

Advertisement

6

Maintenance

6.1

Preventive maintenance schedule

Warning
Warranty - Product Liability
Use only authorized parts. Any damage or malfunction caused by the use of unauthorized parts
is not covered by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Preventive maintenance schedule
Period 1)
Daily
Daily
Daily
Weekly
3-Monthly
3-Monthly
3-Monthly
3-Monthly
3-Monthly
3-Monthly
Yearly
Yearly
Yearly
Yearly
Yearly
Yearly
68
Before carrying out any maintenance, repair work or adjustment, proceed as
follows:
• Stop the compressor.
• Press emergency stop button (S2).
• Close the air outlet valve and open the manual condensate drain valves.
• Switch off the voltage.
• Open and lock the isolating switch.
The operator must apply all relevant
Running hours
Operation
1)
8
Check readings on display.
8
Check that condensate is discharged during loading.
8
Check oil level. Before starting, the level should be in the middle of
the sight-glass.
--
Check the cleanliness of the cubicle filters. Replace or clean if dusty.
--
Clean compressor.
--
Operate safety valve.
--
Remove, dismantle and clean float valve of condensate trap(s).
--
Check for possible leaks.
500
Check the coolers; clean them if necessary. See section Coolers.
--
Remove air filter elements and inspect.
4000
Change oil.
4000
Replace air filter element.
4000
Replace oil filters.
--
Carry out a LED/display test (see section
--
Have all flexibles inspected.
--
Have safety valve tested. (To be carried out by an Atlas Copco
representative)
Safety
precautions.
Instruction book
Test
menu).
APF219617