1. CROSS-CONNECT ROUTING RULE PARAMETERS

A. General Routing Rules
1.01 Several basic rules should be followed in routing
cables to the DSX system:
• Input and output digital signals should always be
in separate cables.
• DS-1, DS-1C, and DS-2 cables should not be routed
above bays or in a lineup associated with electro-
mechanical or crossbar switching equipment.
• DS-1, DS-1C, and DS-2 cables should not run
parallel with power or ground cabling.
B. Cross-Connect Lengths
1.02 The DSX cross-connect jumpers also add to digi-
tal signal-level losses depending on jumper length. To
assure reliable signal levels, maximum jumper lengths
recommended for each DSX frame are:
• DSX-1 and DSX-1C: 85 feet (25.9 m).
• DSX-2: 15 feet (4.6 m).
C. Cross-Connect Types
1.03 The recommended types of cross-connect wire
for each digital rate are:
• DSX-1 and DSX-1C non-shielded, tinned 24
AWG, twisted pair wire.
• DSX-2 Circuits Concentration Bay (CCB) type
cross-connect cords for Bantam modules, and
shielded pair 26 AWG wire with shield grounded
at one end for Longframe (310) panels.