Summary of Contents for UPRENT BBA

  • Page 1 P U M P I N G A N D E N E R G Y S O L U T I O N S PUMP USER MANUAL www.uprent.eu...
  • Page 2 Electric piston pump on the frame Technical specification: Intended use To lower the groundwater level Make / Type BBA / PT150 Maximal flow 90 m3 / h Maximal head 20 mwc Maximal suction lift 9,5m Suction connection 4’’ Discharge connection 4’’...
  • Page 3 User Manual PT150 series Electro Figure 1...
  • Page 4: Table Of Contents

    Contents Description, application and working principle ............3 Description ......................3 Construction of the pump unit ................3 Intended use ......................3 Unintended use.....................4 specification and dimensions ................4 Safety instruction ......................6 Warning stickers....................6 Lifting instructions PT150 pump unit ................8 Moving the pump unit with a forklift ..............9 Pump unit installation ....................
  • Page 5: Description, Application And Working Principle

    Description, application and working principle Description WARNING: This manual is intended to give Important Information that must be followed during Storage, Transportation, Installation, Operation and Maintenance of the Pump-Set. We therefore recommend that this manual is read carefully before the Pump-Set is put into operation.
  • Page 6: Unintended Use

    Use the pump unit only for those applications listed on the specification sheet for the pump unit. − It is not permitted to use the pump unit for any application and/or field of activity other than that for which the pump unit was originally specified and installed without written permission from BBA Pumps. specification and dimensions Pump specifications: Type ......
  • Page 7 Efficiency ......90.7% Star-delta ......Manual Plug ........5 pin - 32 Amp. BBA stackable frame Frame SF10-21 ....Steel hot dip galvanised Dimensions L x W x H ..2070 x 960 x 1200 mm Lifting point ......Fitted with single lifting point Forklift pockets.....
  • Page 8: Safety Instruction

    It is not permitted to make changes to the pump unit without written permission from BBA Pumps. If any changes are made to the pump without the written permission of BBA Pumps, BBA Pumps disclaims all liability. Hearing protection must be worn if the noise emission level exceeds 85 dB(A).
  • Page 9 Diesel is hazardous to the environment, with substantial remediation costs if it leaks into a drain, waterway or the ground. Caution: hot surface Caution: crushing danger Hazardous or irritating substances General hazard Danger: high voltage Danger: magnetic field Wear hearing protection Instructions for use Dispose of in an environmentally responsible manner at the end of the product's useful life.
  • Page 10: Lifting Instructions Pt150 Pump Unit

    Lifting instructions PT150 pump unit DANGER Never walk under a raised load. This can result in a life-threatening situation. WARNING Always disconnect all external connections before moving the pump unit. WARNING Neither the lifting eye on the engine nor the lifting eye of the (bare shaft) pump may be used for transport of the pump unit.
  • Page 11: Moving The Pump Unit With A Forklift

    DANGER The standard lifting eyes on BBA pump units, both in low-noise enclosure and open frame, are NOT designed to lift the additional weight of trailers or other components. It is strictly forbidden to use the standard lifting provision to lift or move the pump units with a higher total weight than stated in the specification sheets.
  • Page 12: Pump Unit Installation

    Note BBA Pumps is not responsible for accidents and damage that result from failure to follow the guidelines in this manual. Such use results in forfeiture of the right to assert any warranty or damage compensation claims.
  • Page 13: Pump - General

    Pump – general To fill the pump housing with water 1. Remove the upper cover from the stone catcher. 2. Fill the stone catcher with water. 3. Close the cover. Control panel If the PT pump is supplied with a star-delta switch, it has three positions: Neutral, Star (1) and Delta (2).
  • Page 14: Checking The Direction Of Rotation

    WARNING Turning the switch too slowly will cause the motor's thermal protection to trip. Return the switch to the neutral position and switch it on again. Checking the direction of rotation WARNING This test may only be performed by authorized personnel with the appropriate training.
  • Page 15: Daily Maintenance Of The Pump

    Daily maintenance of the pump − Check the oil level in drive unit Note If the oil in the pump drive has become whitish in colour, replace the oil. The whitish colour may indicate the presence of excessive condensation water in the oil. −...
  • Page 16: Preperation For Starting

    Preperation for starting 1. Take any necessary measures to ensure that the electrical connections and cables cannot be damaged 2. The voltage and frequency must be checked in advance and must match the motor specifications. This data is shown on the type plate of the motor. 3.
  • Page 17: Starting And Stopping

    Starting and stopping 1. Check the pump type (type plate) and the characteristics of the pump unit, such as: speed, operating pressure, consumed power, operating temperature, direction of rotation, etc. 2. Check whether the pump unit is placed in accordance with the instructions. Pay particular attention to the area around the pump unit.
  • Page 18 Unscrewing the nipple increases the bleed air from the vacuum regulator valve. 10. Check whether both vacuum gauges (1 and 2) on the stone catcher show the same reading. If the readings differ, the grate in the stone catcher needs to be cleaned. 11.
  • Page 19: Stopping

    WARNING Dewatering activities will have an impact on the surrounding area in which water is being extracted from the ground. Settling of the ground occurs during groundwater extraction. This can result in grains of sand moving closer together, which will have an impact on the ground. This can cause cracks in buildings and pipes.
  • Page 20: Monitoring During Operation

    Monitoring during operation 1. During operation check the pump regularly for correct functioning, smooth and vibration-free running abnormal noises and leaks. 2. If the pump has pumped for a long time without having moved water, the pump housing must be filled with water, because the cups shrink after having run dry for a long time.
  • Page 21: Draining The Pump When There Is Danger Of Freezing

    Draining the pump when there is danger of freezing If there is a danger of freezing, a pump used to pump a liquid that may freeze must be drained (while at a standstill). 1. Turn off the engine and open canopy draining ports (covers / plugs) (1). 2.
  • Page 22: Troubleshooting Table

    Troubleshooting table WARNING In the event of a malfunction or abnormal operation, shut off the pump immediately to prevent a dangerous situation and/or damage to the unit. Problem Possible cause Solution No flow while the pump and drive Wellpoint system is not properly Check the wellpoint system and are running.
  • Page 23 Coupling between motor and Replace the coupling pump is defective Thermal protection switch of the Turn switch from stars to delta start/delta switch cuts out. more quickly WARNING If appear some pump defect and cannot find fault immediately contact Uprent technical department.