  • Page 1 ENERWA PLUS 42/40 ENERWA PLUS 45/43 CONDENSING COMBI BOILERS USER MANUAL...
  • Page 2 Enerwa Plus 42/40 Enerwa Plus 45/43 0001_00.W171221  Our company constantly striving to improve our products  This boiler is not designed to be used by persons (including and reserve the right to modify the details given in this children) with limited mental and sensory capabilities or documentation at any time without notice.
  • Page 3: Table Of Contents

    Use of Outside Temperature Sensor (Optional) ..............10 2.4. Customizing Boiler Features ....................11 2.5. Troubleshooting ........................12 2.5.1. Filling/Emptying Radiator Installation ....................... 15 2.6. Recommendations for Economical Use of Boiler .............. 16 2.7. Issues Required To Be Taken Into Consideration For Warranty Conditions ....16 warmhaus.com...
  • Page 4: Introduction

    1. INTRODUCTION Warmhaus was established in 1996 and is an affiliate of Beycelik Holding  Any intervention on a sealed component is forbidden. which produces panel radiators, high capacity wall hung condensing boilers and steel panel radiators. Beycelik Holding has also branches in automotive, energy, tourism and insurance and currently provides employment opportunities for almost 5.000 people.
  • Page 5: Boiler Gas Categories & Destinations

    37 mbar II 2E+3P Propane LPG 37 mbar BE, FR II 2E+3P Propane LPG 37 mbar BE, FR EN 437+A1:2009, Codes for the representation of gases and names of countries and their subdivisions; Part 1: Country codes (ISO 3166-1:2006) warmhaus.com...
  • Page 6: Gas Leakages

    0002_02.W180201 DURING EMERGENCIES NATURAL GAS FIRE AMBULANCE POLICE EMERGENCY DEPARTMENT INFORMATION: You can visit web sites of local gas authorities and NATURAL GAS EMERGENCY sections. Advice: Please take note local emergency phone numbers. 0003_00.W170407 warmhaus.com...
  • Page 7: User's Section

    7. Domestic Hot Water 17. Digital manometer temperature increasing button. 18. Failure indicator. 8. Domestic Hot Water temperature decreasing button. 19. Room thermostat (OpenTherm- OT) connection indicator 9. Flame modulation indicator 10. Radiator (CH) water temperature. 11. Radiator (CH) mode operating indicator. warmhaus.com...
  • Page 8: On/Off/Stand-By Positions

    35 –60 °C with (6) and (7) numbered buttons under the RESET button. LCD screen backlight is turned ON during temperature change, °C symbol flashes besides the DHW 0011_00.W160721 temperature value. LCD screen backlight is turned OFF after adjustment. warmhaus.com...
  • Page 9: Operation In Summer Mode

    LCD screen backlight is turned ON during temperature change, °C symbol repeated, after cycle is completed flashes besides the DHW temperature value. Adjustment value is confirmed will be displayed on backlight is turned after backlight is turned OFF following the adjustment. OFF boiler is now at STANDBY position. 0015_00.W160721 warmhaus.com...
  • Page 10: Use With Room Thermostat (Optional)

    (OPTIONAL) This product can be used together with a room thermostat which can be purchased separately as an accessory. All Warmhaus thermostats can be This product can be used together with a Outside Temperature Sensor connected with dual-wired cables. Carefully read user’s and installation which can be purchased separately as an accessory.
  • Page 11: Customizing Boiler Features

    During this function pump and 3-way valve are activated/ deactivated in order to have deaeration of the hydraulic plant. This function ends pushing again RESET and ”-“ for circle time or at the end of deaeration time: 12 minutes. warmhaus.com...
  • Page 12: Troubleshooting

    > Pump harness 3) Check all radiator valves are open if they are closed. Minimum > Installation blockage 3 meters of radiator must be open 4) RESET boiler and check if problem is resolve 5) Call for authorised service warmhaus.com...
  • Page 13 > Aging or rust on the electrode > Recirculation of exhaust gas into fresh air > Blockage in flue or wrong flue > Electrode position > Cabling disconnections > Combustion calibration > Electronic board > Gas valve failure warmhaus.com...
  • Page 14 1) Call for authorised service combustion (temporarily) code flashing on the screen electrode > Recirculation of exhaust gas into fresh air > Blockage in flue or wrong flue > Electrode position > Combustion calibration > Gas valve failure > Electronic board warmhaus.com...
  • Page 15: Filling/Emptying Radiator Installation

    E. Central Heating Return (CH-3/4" thread) F. Filling Valve 0099_00.W200410 G. Manometer H. Pressure Relief Valve Outlet Figure 7 Filling the boiler I. Drain Point J. Condansate Drain (Ø24 mm) K. Power Supply (230V AC 50 Hz) Figure 8 Boiler connections warmhaus.com...
  • Page 16: Recommendations For Economical Use Of Boiler

    Attention: to preserve the boiler’s integrity and keep the safety features, performance and reliability, you must at least execute maintenance operations on a yearly basis in compliance with national, regional, or local standards in force. We recommend a yearly cleaning and maintenance contract with an authorised local firm. warmhaus.com...
  • Page 17 Enerwa Plus 42 kW, Enerwa Plus 45 kW Boilers Warmhaus All information in the ERP Data Sheet & Product Data Sheet is based on the test results of the SZU Test / BRNO laboratories. PRODUCT FICHE (according to EU regulation No 811/2013 and 814/2013 )
  • Page 18 C feed temperature at heater outlet. As this is the property of Warmhaus Isıtma ve Sogutma Sistemleri San. Tic. A.Ş. It must not be passed on to any person not authorized by Warmhaus Isıtma ve Sogutma Sistemleri San. Tic. A.Ş or be copied or otherwise utilized by anybody without expressed written permission.
  • Page 19 warmhaus.com...