Warmhaus Enerwa Plus 2530 User Manual

Warmhaus Enerwa Plus 2530 User Manual

Condensing combi boilers

Advertisement

ENERWA PLUS
CONDENSING COMBI BOILERS
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Warmhaus Enerwa Plus 2530

  • Page 1 ENERWA PLUS CONDENSING COMBI BOILERS USER MANUAL...
  • Page 2 Enerwa Plus 2530 Enerwa Plus 3035 Enerwa Plus 3540 0001_00.W171221  Our company are constantly striving to improve our  This boiler is not designed to be used by persons (including products and reserve the right to modify the details given children) with limited mental and sensory capabilities or in this documentation at any time without notice.
  • Page 3: Table Of Contents

    2.2. USE WITH ROOM THERMOSTAT (OPTIONAL) .....................10 2.3. USE OF OUTSIDE TEMPERATURE SENSOR (OPTIONAL) .................10 2.4. CUSTOMIZING BOILER FEATURES ..........................11 2.5. TROUBLESHOOTING ..............................12 2.6. RECOMMENDATIONS FOR ECONOMICAL USE OF .....................16 2.7. ISSUES REQUIRED TO BE TAKEN INTO CONSIDERATION FOR WARRANTY CONDITIONS ....16 warmhaus.co.uk...
  • Page 4: Introduction

    1. INTRODUCTION Warmhaus was established in 1996 and is an affiliate of Beycelik Holding  Any intervention on a sealed component is forbidden. which produces panel radiators, high capacity wall hung condensing boilers and steel panel radiators. Beycelik Holding has also branches in automotive, energy, tourism and insurance and currently provides employment opportunities for almost 5.000 people.
  • Page 5: Boiler Gas Categories & Destinations

    37 mbar II 2E+3P Propane LPG 37 mbar BE, FR II 2E+3P Propane LPG 37 mbar BE, FR EN 437+A1:2009, Codes for the representation of gases and names of countries and their subdivisions; Part 1: Country codes (ISO 3166-1:2006) warmhaus.co.uk...
  • Page 6: Gas Leakages

    Ireland 1850 20 50 50 0002_02.W180201 DURING EMERGENCIES NATURAL GAS FIRE AMBULANCE POLICE EMERGENCY DEPARTMENT INFORMATION: You can visit web sites of local gas authorities and NATURAL GAS EMERGENCY sections. Advice: Please take note local emergency phone numbers. 0003_00.W170407 warmhaus.co.uk...
  • Page 7: User's Section

    E02 failure code is temperature decreasing button. indicated if the pressure is 9. Flame modulation indicator lower than this value) 10. Radiator (CH) water 18. Failure indicator. temperature. 19. Room thermostat (OpenTherm- 11. Radiator (CH) mode operating OT) connection indicator indicator. warmhaus.co.uk...
  • Page 8: Selection Of On/Off/Stand-By And Summer/Winter Modes

    35 –60 °C with (6) and (7) numbered buttons under the RESET button. LCD screen backlight is turned ON during temperature change, °C symbol flashes besides the DHW 0011_00.W160721 temperature value. LCD screen backlight is turned OFF after adjustment. warmhaus.co.uk...
  • Page 9: Operation In Summer Mode

    LCD screen backlight is turned ON during temperature change, °C symbol repeated, after cycle is completed flashes besides the DHW temperature value. Adjustment value is confirmed will be displayed on backlight is turned after backlight is turned OFF following the adjustment. OFF boiler is now at STANDBY position. 0015_00.W160721 warmhaus.co.uk...
  • Page 10: Use With Room Thermostat (Optional)

    (OPTIONAL) This product can be used together with a room thermostat which can be purchased separately as an accessory. All Warmhaus thermostats can be This product can be used together with a Outside Temperature Sensor connected with dual-wired cables. Carefully read user’s and installation which can be purchased separately as an accessory.
  • Page 11: Customizing Boiler Features

    During this function pump and 3-way valve are activated/ deactivated in order to have deaeration of the hydraulic plant. This function ends pushing again RESET and ”-“ for circle time or at the end of deaeration time: 12 minutes. warmhaus.co.uk...
  • Page 12: Troubleshooting

    > Pump harness 3) Check all radiator valves are open if they are closed. Minimum > Installation blockage 3 meters of radiator must be open 4) RESET boiler and check if problem is resolve 5) Call for authorised service warmhaus.co.uk...
  • Page 13 > Aging or rust on the electrode > Recirculation of exhaust gas into fresh air > Blockage in flue or wrong flue > Electrode position > Cabling disconnections > Combustion calibration > Electronic board > Gas valve failure warmhaus.co.uk...
  • Page 14 1) Call for authorised service combustion (temporarily) code flashing on the screen electrode > Recirculation of exhaust gas into fresh air > Blockage in flue or wrong flue > Electrode position > Combustion calibration > Gas valve failure > Electronic board warmhaus.co.uk...
  • Page 15 2) Call for authorised service (1) Call the Authorised Service if failure continues. boiler. (2) 81 numbered failure corresponds any blocking in the exhaust gas pipe. In such case, you should consult the authorised service technician before re-starting the warmhaus.co.uk...
  • Page 16: Recommendations For Economical Use Of

    Attention: to preserve the boiler’s integrity and keep the safety features, performance and reliability, you must at least execute maintenance operations on a yearly basis in compliance with national, regional, or local standards in force. We recommend a yearly cleaning and maintenance contract with an authorised local firm. warmhaus.co.uk...
  • Page 17 Enerwa Plus boilers granted Warmhaus ErP & Product Fiche for Warmhaus boilers has been tested and reported on SZU Test / BRNO given bellow; PRODUCT FICHE (according to EU regulation No 811/2013 and 814/2013) Enerwa Plus 24 Enerwa Plus 24...
  • Page 18 C feed temperature at heater outlet. As this is the property of Warmhaus Isıtma ve Sogutma Sistemleri San. Tic. A.Ş. It must not be passed on to any person not authorized by Warmhaus Isıtma ve Sogutma Sistemleri San. Tic. A.Ş or be copied or otherwise utilized by anybody without expressed written permission.
  • Page 19 warmhaus.co.uk...
  • Page 20 NTS pipeline or near an overhead electricity line please call us urgently: please call us urgently: 0800 111 999 0800 40 40 90 FOR ANY TECHNICAL QUERIES PLEASE RING THE WARMHAUS CONSUMER / INSTALLER / TECHNICAL HELPLINE: 0207 1646233...

Table of Contents