Warmhaus EWA 2525C User Manual

Warmhaus EWA 2525C User Manual

Condensing combi boilers
Hide thumbs Also See for EWA 2525C:

Advertisement

Quick Links

EWA 2525C
EWA 2530C
CONDENSING COMBI BOILERS
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Warmhaus EWA 2525C

  • Page 1 EWA 2525C EWA 2530C CONDENSING COMBI BOILERS USER MANUAL...
  • Page 2 EWA 2525C 25 kW EWA 2530C 30 kW 0089_00.WUK210702 0090_00.WUK210702 Our company are constantly striving to improve our This boiler is not designed to be used by persons (including products and reserve the right to modify the details given children) with limited mental and sensory capabilities or in this documentation at any time without notice.
  • Page 3: Table Of Contents

    2.2. USE WITH ROOM THERMOSTAT (OPTIONAL) .....................10 2.3. USE OF OUTSIDE TEMPERATURE SENSOR (OPTIONAL) .................10 2.4. CUSTOMIZING BOILER FEATURES ..........................11 2.5. TROUBLESHOOTING ..............................12 2.6. RECOMMENDATIONS FOR ECONOMICAL USE OF .....................16 2.7. ISSUES REQUIRED TO BE TAKEN INTO CONSIDERATION FOR WARRANTY CONDITIONS ....16 warmhaus.co.uk...
  • Page 4: Introduction

    Maintenance and repairment of the appliance must only be carried out by a competent Gas Safe registered engineer and if in Ireland We thank you for chosing the Warmhaus boiler to maintain your heating an RGI (Registered Gas Installer) and domestic hot water comfort for long years. Warmhaus products are manufactured in accordance with EU standards and exported to many Children must not operate the boiler.
  • Page 5: Boiler Gas Categories & Destinations

    37 mbar II 2E+3P Propane LPG 37 mbar BE, FR II 2E+3P Propane LPG 37 mbar BE, FR EN 437+A1:2009, Codes for the representation of gases and names of countries and their subdivisions; Part 1: Country codes (ISO 3166-1:2006) warmhaus.co.uk...
  • Page 6: Gas Leakages

    0800111999 in case of a natural gas leakage. or in Ireland 1850 20 50 50 0002_02.W180201 DURING EMERGENCIES NATURAL GAS FIRE AMBULANCE POLICE EMERGENCY DEPARTMENT INFORMATION: NATURAL GAS EMERGENCY Please take note local emergency phone numbers. 0003_00.W170407 warmhaus.co.uk...
  • Page 7: User's Section

    10. DHW tap symbol is seen at summer and/or winter position of the combi. Symbol flashes on DHW request or when DHW adjustment is made. 11. Failure indicator. 12. Failure status RESET requirement. 13. Radiator low water pressure. 14. Temperature increasing button. 15. Temperature decreasing warmhaus.co.uk...
  • Page 8 (6) and (7) numbered buttons and this temperature is indicated with (9) numbered indicator for Radiator (CH) and with (11) numbered indicator for Domestic Hot Water. the screen. MODE completed. temperature adjustment button (3). temperature value. warmhaus.co.uk...
  • Page 9 MODE button, and release the button MODE button and release the button after , you can adjust the STANDBY OFF. adjustment, tap symbol can adjust the hot tap water temperature temperature change, °C symbol flashes and decrease (3+15) pressed and °C symbol warmhaus.co.uk...
  • Page 10: Use With Room Thermostat (Optional)

    (OPTIONAL) This product can be used together with a room thermostat which can be purchased separately as an accessory. All Warmhaus thermostats can be This product can be used together with a Outside Temperature Sensor connected with dual-wired cables. Carefully read user’s and installation which can be purchased separately as an accessory.
  • Page 11: Customizing Boiler Features

    During this function pump and 3-way valve are activated/ deactivated in order to have deaeration of the hydraulic plant. This function ends pushing again RESET and ”-“ for circle time or at the end of deaeration time: 12 minutes. warmhaus.co.uk...
  • Page 12: Troubleshooting

    NTC ) faulty E 19 Wrong parameters settled on water on request TsP menu defalut value E 20 CH vertemperature, > Lack of water on the system > Pump blockage TSP 81 value °C open all > Pump harness warmhaus.co.uk...
  • Page 13 (PCB) E 72 > FLOW OR RETURN Sensor occurred E 74 Second CH temperature Probe > FLOW and LIMIT Sensor faulty (double NTC ) faulty E 77 Absolute current values reached electrode flue E 78 reached electrode flue warmhaus.co.uk...
  • Page 14 > Strong flue blockage > Wrong flue electrode E 84 detected (supposed) low gas screen E 87 E 88 E 89 electrode flue E 90 Unable to regulate electrode screen flue E 92 electrode flue E 93 Unable to regulate electrode flue warmhaus.co.uk...
  • Page 15 SW error, board start-up error fault E 99 problem (1) Call the Authorised Service if failure continues. boiler. (2) 81 numbered failure corresponds any blocking in the exhaust gas pipe. In such case, you should consult the authorised service technician before re-starting the warmhaus.co.uk...
  • Page 16: Recommendations For Economical Use Of

    We recommend a yearly cleaning and maintenance contract with an authorised local firm. warmhaus.co.uk...
  • Page 17 Product FICHE & ErP Data granted Manufacturer: ErP Data Warmhaus Ewa-2525 C 25 kW Ewa-2530 C 30 kW Ewa-2525C Ewa-2525C Ewa-2530C Ewa-2530C Rated heat output (Prated or Psup) 42.14 42.14 42.14 42.14 kWh (*) GJ (**) — — (**) Fuel HANDING OVER warmhaus.co.uk...
  • Page 18 0.057 0.057 Stby 0.000 0.000 0.000 0.000 42.14 42.14 42.14 42.14 mg/kWh 0.117 0.169 0.117 0.169 elec 14.809 23.152 14.809 23.152 fuel Brand Name Warmhaus Manufacturer adress C and for other heaters 50 C feed temperature at heater outlet. warmhaus.co.uk...
  • Page 19 warmhaus.co.uk...
  • Page 20 NTS pipeline or near an overhead electricity line please call us urgently: please call us urgently: 0800 111 999 0800 40 40 90 FOR ANY TECHNICAL QUERIES PLEASE RING THE WARMHAUS CONSUMER / INSTALLER / TECHNICAL HELPLINE: 0207 1646233...

This manual is also suitable for:

Ewa 2530c

Table of Contents