Warmhaus LAWA 18 Installation & User Manual

Warmhaus LAWA 18 Installation & User Manual

Conventional combi boilers
Table of Contents

Advertisement

LAWA &
LAWA PLUS
CONVENTIONAL COMBI BOILERS
INSTALLATION & USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Warmhaus LAWA 18

  • Page 1 LAWA & LAWA PLUS CONVENTIONAL COMBI BOILERS INSTALLATION & USER MANUAL...
  • Page 2 Lawa LawaPlus Enerwa E24 EnerwaPLUSE24...
  • Page 3: Table Of Contents

    INDEX DEAR WARMHAUS CUSTOMER .........................4 1.1. GENERAL WARNINGS ................................4 1.2. GENERAL WARRANTY CONDITIONS ..........................4 1.3. GAS LEAKAGES ..................................5 INSTALLATION PERSONNEL SECTION ......................5 2.1. CONTENTS OF PACKING BOX ............................5 2.2. COMBI INSTALLATION RULES ............................6 2.2.1. General Rules for Installation Places of Combi Boilers ....................6 2.2.2.
  • Page 4: Dear Warmhaus Customer

    - Directive 2014130/EU performing project and etude studies. Please visit the below given web site of Warmhaus for acquiring more In order to enable use of the combi with LPG tubes or LPG tanks, detailed information regarding legal regulations on installation of gas fired conversation of the combi should be performed by our authorized heating devices: www.warmhaus.com...
  • Page 5: Gas Leakages

    2.1. CONTENTS OF PACKING BOX I. Installation Scheme (Figure 1) II. User Guide (Figure 2) Warmhaus is sold as two boxes containing combi and flue set. Combi box III. Connection Accessories (Figure 3) contains below listed materials and smaller box contains exhaust gas flue a.
  • Page 6: Combi Installation Rules

    WARMHAUS LAW 2.2.2. Places Not Suitable for Installing Hermetical Combi Boilers CENTRAL HE DOMESTIC H •...
  • Page 7: Natural Gas And Lpg Connection (Device Category I2H, Ii2H3P)

    In case of failing to fulfil these conditions, combi will not be covered under warrantee by Warmhaus Authorized Services. Figure 7 LawaPlus Combi dimensions and connections Warmhaus LawaPlus...
  • Page 8: Radiator And Domestic Hot Water Installations

    Flue accessory sets to be used in exhaust gas installation of Hermetic combi comply with the heat loss calculation. boilers should be original Warmhaus flue sets and they should be used • Radiator installation should be designed as resisting to at least 6 bars.
  • Page 9: Flue Accessories

    Each 90° elbow usage requires to decrease maximum 100 cm from horizontal/ vertical distance. Ø 60/100 Conventional Condensed It is the accessory which must be installed to boiler flue 153.11.660.600011 Vertical Adapter output if Vertical Flue Set is used. warmhaus.com...
  • Page 10: Installation With Horizontal Flue Sets (Ø60/100 Mm)

    • Make required flue selection for the external flue connection If the an authorized Warmhaus dealer according to requirements, non-original standard flue set is not adequate, please select most suitable elements hermetic flue accessories should never be used.
  • Page 11: Installation With Horizontal Flue Sets

    + b + c + d < 4 m Figure 18 Vertical flue set installation Figure 16 II. Two 90° elbow sample flue installations a- Standard Flue Set Elbow (90°) b- Flue Extension Pipe c- Additional 90° Elbow d- Standard Flue Set Pipe warmhaus.com...
  • Page 12: Hermetic Flue Type Use

    It is dangerous and unacceptable to use gas and water connection pipes for earthing. Implementation WARNING! WARMHAUS A.Ş. cannot be held responsible for any damage or loss to individuals or property arising from failing to provide earth = 0.3 m.
  • Page 13: Optional Controls: Room Thermostat, External Weather Temperature Sensor And Others

    255V in accordance with standards. If this range is not maintained in your electricity grid, (195-255V) it is recommended to use voltage regulator. Contact our Authorized Warmhaus Service for replacement of the cable. Power supply cable should follow the defined route. If the adjustment card is replaced, please use 2A or 3,15A speed type fuses.
  • Page 14: Hydraulic Installation Rules

    2.3.4. Controls for Initial Operation of Combi In order to prevent void warranty scope, initial startup of the combi must be performed by the Warmhaus Authorized Service. Below given initial 2.3.1. Radiator (Heating) Water Structure preparations should be performed prior to authorized service appointment...
  • Page 15: User Section

    After operations are completed, have the combi controlled by Warmhaus Authorized Service First start should be performed by the Warmhaus Authorized Service for prior to starting the combi. your safety and preventing void warranty scope. Our Authorized Service...
  • Page 16 LAWA combi screens consist of navy blue colored backlight LCD screen, 2 buttons, Radiator (3) and Hot Tap Water (4) and 2 pcs, RESET (2) and CH: (System) Central Heating DHW: Domestic Hot Water MODE (1) pushbuttons. warmhaus.com...
  • Page 17: Selection Of On/Off/Standby And Summer/Winter Modes

    The adjusted value shall be confirmed after flashing for 4-5 seconds after releasing the button and continues to display the temperature value in the installation. warmhaus.com...
  • Page 18 • Service technician function radiator + tap displayed. (Only for authorized service, wait for the function to end without pressing any button in such case!) Figure 29 Lawa Plus combi control panel screen warmhaus.com...
  • Page 19: Selection Of On/Off/Standby And Summer/Winter Modes

    A digital manometer indicating the installation pressure is located on the lower middle section of the screen and also existing radiator installation temperature is seen on the screen at the same time and screen light is turned off. warmhaus.com...
  • Page 20: Shutting Off The Combi

    Making intervention on the device by unauthorized persons during installation (Figure 33). Installation Instruction: Device installation shall only be performed by the Warmhaus Authorized Service. The dual cable required for installation is supplied by the dealer/consumer. Figure 32 Outside weather temperature sensor Figure 33 Outside temperature sensor operation curves warmhaus.com...
  • Page 21: Customizing Combi Features

    5-) Reset & Restart boiler Central heating FLOW tem- Boiler does not work, E05 > Central heating FLOW 1-) Call for authorised service at first E 05 perature sensor faulty error code flashing on the temperature sensor faulty screen warmhaus.com...
  • Page 22 3-) Check all radiator valves are open if they are closed open of all > Installation blockage minimum 3 meters of radiator must be open 4-) RESET boiler and check if problem removed 5-) Call for authorised service at first warmhaus.com...
  • Page 23: Issues Required To Be Taken Into Consideration For Warranty Conditions

    94 at section E 74 4.29 if its out of tolerance replace double NTC 3-) Check cabeling and connectors between double NTC and board 4-) Reset & Restart boiler warmhaus.com...
  • Page 24 Lawa / error code flashing on the path then RESET the boiler E 83 Lawa Plus models screen > Blokage on flue or wrong 2-) IF problem persist Call for authorised service flue > Combustion calibration warmhaus.com...
  • Page 25 1-) Call for authorised service at first tion (temporarily) error code flashing on the electrode screen > Recirculation on fluegas path > Blokage on flue or wrong E 93 flue > Electrode position > Combustion calibration > Gas valve failiure > Electronic board warmhaus.com...
  • Page 26 Thus, you can adjust temperature of your Ensure balancing our pressure distribution of your radiator installation room as you wish, and also you can acquire approximately 6% power saving within the house by making reduction adjustments from radiator valves. with every degree of temperature decrease. warmhaus.com...
  • Page 27 4.3. ISSUES REQUIRED TO BE TAKEN INTO CONSIDERATION FOR WARRANTY CONDITIONS This warranty given by Warmhaus does not cover elimination of failures arising from abnormal use of the product and also out of the warranty scope for below given situations:...
  • Page 28 Lawa 18 / Lawa 32 / TECHNICAL DATA UNIT Lawa 24 / LawaPlus 24 Lawa 28 / LawaPlus 28 LawaPlus 18 LawaPlus 32 Natural Gas Natural Natural Natural Natural Gas Circuit (Supply Pressure) (mbar) Natural Gas (20) (20) Gas (20)
  • Page 29 GAS CATAGORIES AND COUNTRIES Appliance categories Supply pressures [mbar] Used gas Countries of destination Lawa 18 Lawa 24 Lawa 28 Lawa 32 Lawa Plus 18 Lawa Plus 28 Lawa Plus 32 AT, BG, CH, CZ, DK, EE, ES, FI, GB, GR, IE,...
  • Page 30 warmhaus.com...
  • Page 31 All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request.
  • Page 32 LAWA & LAWA PLUS...

Table of Contents