10 Checking the Blower
► Press the blower onto the ground with the left
hand on the motor and step onto the base
plate with the right foot.
► Pull the starter grip slowly with your right hand
until you feel it engage.
► Pull the starter grip quickly and allow the
starter rope to rewind several times until the
engine runs.
► Blip the throttle trigger (2).
The choke lever (4) springs to position . The
engine runs at idling speed.
9.4
Shut off the engine
1
► Move the Master Control Lever (1) to posi‐
tion
.
The engine stops and the Master Control lever
(1) springs back to position .
► If the engine does not stop:
► Move the choke lever to position
The engine stops.
► Do not use the blower. Consult a STIHL
servicing dealer.
The Master Control lever is defective.
10 Checking the Blower
10.1
Checking the controls
Shut off the engine
► Start the engine.
► Move the Master Control Lever to position
The engine stops.
► If the engine does not stop:
► Move the choke lever to position
The engine stops.
► Do not use the blower. Consult a STIHL
servicing dealer.
The Master Control lever is defective.
10.2
Checking the nozzle
► Shut off the engine.
0458-459-0121-E
► Check whether the wear mark on the blower
tube is visible.
► If there is no visible wear mark on the blower
tube: Do not use the blower and contact your
STIHL dealer for assistance.
► If you have any doubts, be sure to consult a
STIHL dealer.
11 Operating the Blower
11.1
.
► Carry the blower on your back.
► Hold the blower unit by the operating handle
with your right hand so that your thumb enclo‐
ses the control handle.
11.2
.
.
► Point the nozzle at the ground.
► Move forward slowly in a controlled manner.
11.3
Any desired blowing force can be continuously
locked via the Master Control Lever.
Holding and Guiding the
Blower
Blowing
Activating and Deactivating the
Power Lock
English
11