FUNCTIONS
AE – Iris priority
The iris can be set freely by the user to 18 steps between F1.4 and Close.
The gain and shutter are set automatically, according to the brightness of the subject.
AE – Gain priority
The gain can be set freely by the user to 8 steps between –3 dB and +18 dB.
The shutter speed is fixed and the iris is set automatically, according to the brightness of the subject.
AE – Manual
The shutter speed (20 steps), iris (18 steps) and gain (8 steps) can be set freely by the user.
Setting
Data
value
11
F1.4
10
F1.6
0F
F2
0E
F2.4
0D
F2.8
0C
F3.4
0B
F4
0A
F4.8
09
F5.6
Setting
Data
07
06
05
04
03
02
01
00
Setting
Data
value
08
F6.8
07
F8
06
F9.6
05
F11
04
F14
03
F16
02
F19
01
F22
00
CLOSE
value
18 dB
15 dB
12 dB
9 dB
6 dB
3 dB
0 dB
–3 dB
FCB-IX47/IX47P
FCB-IX470/IX470P
7