Intrinsic Safety Warnings
•
MAKE SURE THE AREA IS FREE FROM HAZARDOUS GAS WHEN INSTALLING, SERVICING,
REMOVING, CLEANING OR TOUCHING UNIT.
•
INSTALLATION, SERVICING, REMOVAL SHOULD ONLY BE DONE BY
QUALIFIED/AUTHORIZED PERSONNEL.
•
USE ONLY HONEYWELL ELSTER MANUFACTURED BATTERY PACKS
WITH PART NUMBER# 32448424.
•
NONE OF THE BATTERY PACKS SHALL BE RECHARGED UNDER ANY CIRCUMSTANCES.
•
POTENTIAL ELECTROSTATIC CHARGING HAZARD – USE DAMP CLOTH FOR CLEANING
•
SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY
Intrinsic Safety Conditions
•
The housing of the equipment may generate an ignition-capable level of
electrostatic discharge. Therefore, the equipment shall not be installed
in a location where the external conditions are conducive to the build-up of
electrostatic charge on such surfaces. This is particularly important if the
equipment is installed in a Zone 0/Division 1 location. In addition, the device shall only be
cleaned with a damp cloth and shall not be stored or operated in a hazardous location if
strong electrostatic charge generating processes can occur.
•
The equipment shall only be powered using single D-cell pack #32448424.
•
This pack may be replaced in hazardous area and shall not be altered in any way.
•
The SIM connection (J1) shall only be used for SIM card.
•
The connection of an external antenna is not allowed at RF connector J2.