MIL'S HOSPITAIR PACK S MVA 8 General Installation And Maintenance Instructions

MIL'S HOSPITAIR PACK S MVA 8 General Installation And Maintenance Instructions

Hide thumbs Also See for HOSPITAIR PACK S MVA 8:

Advertisement

-
ENGLISH VERSION
-
GENERAL INSTALLATION AND MAINTENANCE INSTRUCTIONS
HOSPITAIR PACK S (MV) – 11 bar
SAFETY RULES see manual n°511927 / Spare parts list and maintenance instructions for compressors
First apposition of the EC marking: 2009
This document must not be disclosed or reproduced without permission from MIL'S.
Failure to respect this requirement may lead to prosecution.
-
12/16 – MANUAL N° 520003 VERSION 5
-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HOSPITAIR PACK S MVA 8 and is the answer not in the manual?

Questions and answers

Summary of Contents for MIL'S HOSPITAIR PACK S MVA 8

  • Page 1 SAFETY RULES see manual n°511927 / Spare parts list and maintenance instructions for compressors First apposition of the EC marking: 2009 This document must not be disclosed or reproduced without permission from MIL'S. Failure to respect this requirement may lead to prosecution.
  • Page 2: Table Of Contents

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar CONTENTS SECTION 1.   INTRODUCTION   1.1.   ............................ 3   ENERAL POINTS 1.2.   ..........................3   PECIFICATION PLATES SECTION 2.   CHOICE OF ROOM   2.1.  ...
  • Page 3 General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar MEANING OF SYMBOLS USED IN THESE INSTRUCTIONS Symbols are used in these instructions to help you understand them and to indicate particular points which you need to act upon or consider. Those symbols are: Reading symbol: to refer to the operator manual / instructions manual.
  • Page 4: Introduction

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar SECTION 1. INTRODUCTION We strongly advise you to read these installation instructions, before first switching on your air unit. The damage that could be caused by setting the machine up or installing it incorrectly would not be covered by our guarantee.
  • Page 5: Room Ventilation

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar 2.1. Room ventilation The section of the inlet air opening is the ratio of the compressor ventilation flow on recommended air flow velocity (= 3 m/s) [maxi. 5 m/s]. Example: The compressor ventilation flow being of 2500 m³/h (= 0.694 m³/s), the grid section will be 0.694/3 = 0.2 m²...
  • Page 6: Description Of An Air Plant: Hospitair Pack S

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar SECTION 3. DESCRIPTION OF AN AIR PLANT: HOSPITAIR PACK S 3.1. Schematic diagram: 1 line 3.2. Schematic diagram: several lines 3.3. Description of the air production assembly architecture The air is sucked in by the compressor through the air filter then is compressed and injected through the cyclone/filter fitted with an electronic air vent valve with an alarm contact.
  • Page 7 General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar 3.4.2. Adsorption dryer The oxygen generator gives the order for the adsorption dryer to start. As long as the generator is active, the adsorption dryer operates. When the oxygen generator gives the order for the adsorption dryer to stop, the dryer will stop at the end of the cycle. 3.4.3.
  • Page 8: Installations

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar INSTALLATIONS 3.5. Dimensions 3.5.1. Compressors HOSPITAIR PACK S HOSPITAIR PACK S HOSPITAIR PACK S MVA 8 / MVB 12 / MVB 16 MVC 19 / MVC 23 MVD 31 / MVE 38 / MVE 46 3.5.2.
  • Page 9: Electric Power Supply

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar SECTION 4. ELECTRIC POWER SUPPLY See the electric diagram attached to this manual (terminals and electrical connections) All operations on the air plant shall be performed with the air plant switched off. Connection shall be made by the exploiting.
  • Page 10: Summary Of Electric Connections

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar Screw the connector on the plug the regulation unit PROCOM-2 NB: if the 10-meter long cable is not enough, an extension can be added. Contact us. 4.3. Summary of electric connections 400V + Terre Alarm report: The connection between Alarm report on automate units must be done by the person in charge of the...
  • Page 11: Air Connections

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar SECTION 5. AIR CONNECTIONS Connect the air production unit to generator taking care to observe the correct connecting hosing and pipe cross- sections.  Connect output [1] from each filter system to receiver [2]. ...
  • Page 12: Commissioning

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar SECTION 6. COMMISSIONING 6.1. First step  Check the oil level of compressors.  Before starting the equipment, first read all the running operation and maintenance manuals (screw compressor, ADSORMIL'S air dryer, PRO XY).
  • Page 13: Electronic Vent Valve Test

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar 6 months 12 months 24 months 3 years 5 years COMPRESSOR Refer to the maintenance manual Refer to general installation and maintenance FILTRATION CHAIN instructions or maintenance manual ●...
  • Page 14 General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar 0 to 600 litres: Tmin = -10°C 600 to 2000 litres: Tmin = 0°C Tmax = 60°C Tmax = 50°C These temperature values are given as a function of the capacity and only apply to the pressure receivers used with our HOSPITAIR products.
  • Page 15: Test Pressure

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar SECTION 9. TEST PRESSURE Each equipment under pressure was tested individually by its respective manufacturer. The connection of the equipment is carried out by assembly without welding. SECTION 10. PROTECTION AGAINST ONVERPRESSURE The various modules constituting the compressed air unit, object of this technical manual, are protected by relief valves as indicated in the table hereafter:...
  • Page 16: Electromagnetic Compatibility

    General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar SECTION 12. ELECTROMAGNETIC COMPATIBILITY The units with PROCOM2 automate needs special precautions regarding EMC. The units with PROCOM2 automate has to be installed and put into service according to the EMC requirements joined in the following tables Guidance and manufacturer’s declaration –...
  • Page 17 General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar Guidance and manufacturer’s declaration – electromagnetic immunity - for ME equipment and ME systems that are not life- supporting The units with PROCOM2 automate is intended for use in the electromagnetic environment specified below. The customer or the user of the units with PROCOM2 automate should assure that it is used in such an electromagnetic environment.
  • Page 18 General installation and maintenance instructions HOSPITAIR PACK S (MV) - 11 bar The units with PROCOM2 automate can be affected by communication portables or mobiles RF’s equipment. Recommended separation distances between portable and mobile RF communications equipment and the units WITH PROCOM2 AUTOMATE The units with PROCOM2 automate is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
  • Page 20  ...

Table of Contents

Save PDF