Panasonic NB-G100P Manual page 7

Table of Contents

Advertisement

No.
Operation
10 -
Press the key "Light".
11
-
Press the key "
the "Temperature Control".
12
-
Press the key "
the "Timer".
13 After checking, press the power button to finish the test.
3.2. Operation check test for the heater and thermistor
The precondition for this test is to set the baked color to "Medium".
No.
Operation
-
1
Connect the power cord
to the 120 V a.c outlet.
-
2
The power supply button
is pushed.
-
3
Press the "Toast" key.
4 Disconnect the power cord from the outlet (to carry out the check test for the thermistor).
-
5
After 10 sec., make sure
that the power button is
set to "ON". Then, connect
the power cord to the 120
V a.c outlet with the
temperature "
" and
the timer "
" keys
pressed. (test mode)
Working description
Display and buzzer information
-
The power lamp comes on.
-
The buzzer sounds once when the key is
operated.
-
The "Light" lamp comes on.
-
The power lamp comes on.
-
The buzzer sounds once when the key is
" on
operated.
-
The temperature lamps "250" and "500" come
on in this order repeatedly.
-
The power lamp comes on.
" on
-
The buzzer sounds once when the key is
operated.
-
"8" and "8.5" on the timer display blink in this
order repeatedly.
Working description
Display and buzzer information
-
The power lamp comes on.
-
Power supply indication light lighting.
-
The "Toast" lamp comes on.
-
The cooking time display "2.5 min." blinks.
-
The cooking time display comes to "0 min."
-
The buzzer sounds 12 times.
-
Only the power lamp comes on.
-
The power lamp comes on.
-
"8" and "8.5" on the timer display blink in this
order repeatedly.
* "8" and "8.5" on the timer
display won't blink.
Action
Action
* The heater
is heated up
to become
red.
-
The heater turns
off.
7
Items to be checked
* Check the Algon Heater's
wiring in this step.
-
When power is supplied to the
Heater for 1 sec.
-
The oven inside becomes bright.
-
The key"
" to the temperature
not accepted.
-
The timer key "
" won't
accepted.
Items to be checked
-
Check the power cord
-
The power cord is normal.
-
Check the algon heater.
*2 The upper heater has
failure.
*2 The lower heater has
failure.
Check if the mode changes
the test one.
* The mode change was
ended in failure.
(Perform the operation
again.)

Advertisement