Panasonic NB-G100P Manual page 13

Table of Contents

Advertisement

The points in reassembly
How to distinguish between upper heater assy. and lower heater assy.
Heater
Upper heater assy.
Lower heater assy.
6.7. Disassembling the algon heater assy.
1. Remove the 2 screws E.
2. Remove the fasten terminal (CN5: red and CN8: white) from the
P.C. board unit.
3. Roll out the tab locking the algon heater assy. with a pair of small
pliers.
4. Remove the heater plate.
5. Remove the algon heater assy.
Difference
Resistance at
room
temperature
The pipe is
Approx. 31
yellow.
The pipe is
Approx. 26
white.