  • Page 1 7854T INSTALLER MANUAL GEMINI Technologies S.r.l. Via Luigi Galvani 12 - 21020 Bodio Lomnago (VA) - Italy Tel. +39 0332 943211 - www.gemini-alarm.com ISO 90001 Certified Company AC2684 Rev.03 - 06/22 Made in Italy...
  • Page 2: Table Of Contents

    2.0 - ALARM POSITIONING CONTENTS PAGE 02 1.0 - PRELIMINARY ADVICE............PAGE 03 2.0 - ALARM POSITIONING............Do not install the alarm unit in this PAGE 04 3.0 - ACCESSORIES POSITIONING..........position as water ingress over time PAGE 0 3.1 - Electronic key receptacle............may seep through the rubber PAGE 0 3.2 - Contact switch (optional)............
  • Page 3: Accessories Positioning

    3.0 - ACCESSORIES POSITIONING 4.0 - ALARM UNIT SEALING 3.1 - Override key receptacle To seal the alarm, position the The receptacle with built-in LED must be installed where it can readily be seen rubber cap over the external edge and accessed by the user.
  • Page 4: Alarm Positioning For Maximum Sensitivity

    5.0 - ALARM POSITIONING FOR MAXIMUM SENSITIVITY To ensure correct operation of the built-in motion sensor, install the alarm as illustrated below. Figure 4: motion sensor operation with siren facing sideways (only for vehicles with a side stand). The alarm can be fitted on either the right or left side of the vehicle as long as the siren is turned towards the right side of the vehicle (opposite to the stand).
  • Page 5: Electrical Connections

    WIRING CONNECTOR 7.0 - WIRING DIAGRAM AND PINOUT 6.0 - ELECTRICAL CONNECTIONS WIRE COLOR CONNECTION Black marked “M” Connect to battery negative terminal lack marked “B1” Engine immobilization Black marked “R” Connect to battery positive terminal Brown Earth for override key Orange Connect to right turn indicator light 3 Black marked “M”...
  • Page 6: Double Engine Immobilization

    8.0 - DOUBLE ENGINE IMMOBILIZATION 8.2 Grounded wire 8.1 - Electronic ignition Example N.1 Example N.2 Example N.1 Example N.2 BLACK H1 BLACK HB BLACK H1 BLACK HB N.C. N.C. N.C. N.C. BLACK B1 BLACK B BLACK B1 BLACK B COM.
  • Page 7: Pairing New Devices

    9.2 - Without BROWN/GREEN wire ground connection 9.0 - PAIRING NEW DEVICES 9.1 - With BROWN/GREEN wire ground connection To pair a new device, proceed as follows: The alarm is supplied with 2 remote controls and 1 override key but other Make sure passive arming is disabled.
  • Page 8: Programmable Features

    After pressing both buttons simultaneously (step 4), program the features 10.0 - PROGRAMMABLE FEATURES according to your needs. To either enable or disable one of the programmable features proceed as indicated hereafter. TO ENABLE TO DISABLE NB: Remember to ALWAYS arm and disarm the alarm before programming. Press button 2 Press button 1 Button 1: TO ENABLE...
  • Page 9: Remote Control

    12.0 - REMOTE CONTROL 13.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT The remote control has 2 different function buttons each of which corresponds The present device falls within the field of application of the current WEEE to a control signal that activates a selected action according to the operational Directive.