Example For Mintime/Maxtime Logic - netvox R313B User Manual

Wirelesslight sensor
Table of Contents

Advertisement

(2) Read Configuration:
Downlink: 024B000000000000000000
Response:
824B003C003C0100C80000(Current configuration)

5.3 Example for MinTime/MaxTime logic

Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
Max Time
S
leeping (Min Time)
1H
Wakes up and
collects data
REPORTS 2.8V
Note:
MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange
value.
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
Sleeping (MinTime)
th
0H
15
M
Wakes up and
Wakes up and
collects data
collects data
2.8V
REPORT 2.8V
Does not report
2H
Wakes up and
collects data
REPORTS 2.8V
MaxTime
sleeping
sleeping
th
30
M
45
Wakes up and
Wakes up and
collects data
collects data
2.8V
Does not report
Does not report
Max Time
S
leeping (Min Time)
sleeping
th
M
1H
Wakes up and
collects data
REPORTS 2.8V
2.8V
7
3H
Wake up and
collects data
REPORTS 2.8V
2H