oPtIoNaL FaN BLower SySteMS
electrical Grounding Instructions: this
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
the black and white wires on the aC box
wiring harness are marked 'Blower', 'Light'
and 'aux'. It is important to use the wires
marked 'Blower' or the control will not work
correctly.
BLotSDVSC SIGNature CoMMaND BLower
f i r e - p a r t s . c o m
Blower (300w Max)
Blower (300w Max)
The BLOTSDVSC Blower Kit requires the SCSACM A/C
Module and the TSFSC remote to install and operate this
kit. Refer to blower instructions for installation.
20301852
To Junction Box
In Fireplace
Optional
{
Light
WHITE
BLACK
WHITE
BLACK
{
BLACK
Optional
WHITE
AUX
Figure 50 -
BLOTSDVSC Blower Wiring Diagram
FP2684
BLOTSDVSC fan wiring
electrical connections should only be
performed by a qualified licensed electrician.
Main power supply must be turned off before
connecting the fan to the main electrical
power supply or performing service.
GREEN
Connector
Pin To Contro  l  Box
Control Box
DVBL7 Series Gas Fireplace
optional aC
Module
FP2103